Troubleshooting
Slide the switch on the PC card
up to the nonprotected position
Figure 6-1. Write-Protect Tab on a Backup/Restore PC Card
Enter Backup Programming—Automatic (#123) and select Option 3 to clear the
alarm display (see ''Clearing a Backup-Failure Alarm'' on page 6-3).
Display Shows "Backup Failed:Check Card"
at Idle Extensions 10 and 11
Possible Cause 1: The Backup/Restore PC Card was removed while the backup
was in progress.
What to do: Check to see whether the PC Card was removed. If it was not, go to
Possible Cause 2. If it was, power down the system, reinsert the PC Card, and
reapply power to the system. The backup is rescheduled for the next day at
2:00 a.m.
Enter Backup Programming—Automatic (#123) and select Option 3 to clear the
alarm display (see ''Clearing a Backup-Failure Alarm'' on page 6-3).