Installation Guide
Hard power cords should be fastened in the terminal connection area to prevent stress on terminal connection
and cable.
Do not use self-tapping screws to fasten terminals.
Power cords of the same type and in the same cabling direction should be bundled up into cable bunches,
with cables in cable bunches clean and straight.
Binding by using buckles should be performed according to
Table 7-2
Cable Bunch
Cable Bunch Diameter
10 mm (0.39 in.)
10 mm to 30 mm (0.39 in. to 1.18 in.)
30 mm (1.18 in.)
No knot is allowed in cabling or bundling.
For wiring terminal blocks (such as air switches) of the cord end terminal type, the metal part of the cord end
terminal should not be exposed outside the terminal block when assembled.
Table
7-2.
Distance between Every Binding Point
80 mm to 150 mm (3.15 in. to 5.91 in.)
150 mm to 200 mm (5.91 in. to 7.87 in.)
200 mm to 300 mm (7.87 in. to 11.81 in.)