(2) Configure basic information of a view.
Table 6-2
View Configuration Parameters
Parameter
View Name
OID
Type
Note
A least one OID rule must be configured for a view. Otherwise, an alarm message will appear.
(3) Click OK.
Description
Indicates the name of the view.
1-32 characters. Chinese or full width characters are not allowed.
Indicates the range of OIDs included in the view, which can be a single
OID or a subtree of OIDs.
There are two types of rules: included and excluded rules.
The included rule only allows access to OIDs within the OID range.
Click Add Included Rule to set this type of view.
Excluded rules allow access to all OIDs except those in the OID
range. Click Add Excluded Rule to configure this type of view.