Installing the operating system
Installing SVR4 OS - continued
5. Once the "MPU Clock Speed" message has appeared, press the Break key to interrupt the system
diagnostics checking. After you have pressed the Break key, the system displays the message
System Break key detected. The following menu should appear:
1. Continue System Start Up
2. Select Alternate Boot Device
3. Go to System Debugger
4. Initiate Service Call
5. Display System Test Errors
6. Dump Memory to Tape
Enter Menu #:
If you fail to interrupt the boot sequence, the system will boot anyway but it will boot from disk so you
won't be able to go to step 5. This will take approximately 5 minutes longer.
6. At the menu, select option 3. Go to System Debugger. The following prompt displays:
187 - Bug>
7. Enter the following at the 187 - Bug> prompt:
>bo 0 40 COREunix (for cartridge drive)
>bo 0 50 COREunix (for DAT drive)
8. A message similar to the following is displayed next (depending on drive), then the system boots from the op-
erating systems tape.
Booting from: VME187, Controller 0, Drive 40
Loading: COREunix
9. The system continues to boot. When the custom installation begins, the following messages display:
Custom UNIX SYSTEM V/88 Release 4 Version 4.3 for CC MIS
Base O/S Version
Customization Version
INSTALLATION & MAINTENANCE SYSTEM
***> Creating device nodes . . .
10. After the messages in step 8 appear, the following prompt displays:
OPTIONS FOR PROCEEDING
========================
The following commands are available:
i - Install the operating system
c - Change processor type of installed system
m - Enter a maintenance shell
---> Enter your selection [i]:
C-2
- or -
: FH40.43 RM04 P007
: NTOS 2.x
Release 5.2
Continued on next page ...
297-2671-545