System Log Messages
Undefined X.25 event <nnn> received (ignored)
The X.25 driver indicated an event occurred that is not defined The "nnn" field gives the event type number.
(Action Code: B)
Updating physical link configuration
DMSLINK has been notified of a potential change in the status of its X.25 port. This log appears when the "X.25
Diagnostics" screen is used to disable or enable an X.25 link. (Action Code: J)
Value range error in non-LM request
The switch is reporting a value range error in a request that is not a load management request. No action is taken
by DMSLINK other than reporting this error. For LM request messages encountering a value range error, this
error condition is passed back to the CCLINK process for appropriate handling. (Action Code: L)
X.25 bind request failed - reason: <reason description>
DMSLINK was unable to bind itself to the X.25 port used to communicate with the switch. (Action Code: AC)

Fatal Error Messages

Fatal error messages are generated by DMSLINK in response to conditions which prevent the process from continu-
ing normal execution. This section lists these error messages.
ACD pool protocol "xxxxx" is not supported
The ACD pool protocol datafilled on the switch for this link is invalid. (Action Code: Q)
Data transmit local failure on <x25 port>
The X.25 driver returned an error while attempting to transmit data to the switch via the X.25 port identified by
<x25 port>. (Action Code: F, B)
Invalid parameter [c] in initialization file
An invalid parameter was found in the initialization file. The invalid parameter is identified by "[c]" in the error
message. (Action Code: B)
Invalid pool password
The password for the pool as read from the system database does not match the password datafilled on the switch
for the pool. (Action Code: M)
Invalid pool protocol
The switch is not running the correct protocol version. (Action Code: M)
Local failure to open X.25 driver <name>
The attempt to open the X.25 device driver failed. The device driver's full pathname is given by <name>. (Action
Code: B)
Maximum logons exceeded
The switch has disallowed the DSP's request to logon because it already has the maximum number of simulta-
neous logons in progress. (Action Code: K, S)