4
Command Line Interface

sntp poll

This command sets the interval between sending time requests when the switch is
set to SNTP client mode. Use the no form to restore to the default.
Syntax
sntp poll seconds
no sntp poll
seconds - Interval between time requests. (Range: 16-16384 seconds)
Default Setting
16 seconds
Command Mode
Global Configuration
Command Usage
This command is only applicable when the switch is set to SNTP client mode.
Example
Console(config)#sntp poll 250
Console(config)#
Related Commands
sntp client (4-54)

show sntp

This command displays the current time and configuration settings for the SNTP
client, and indicates whether or not the local time has been properly updated.
Command Mode
Normal Exec, Privileged Exec
Command Usage
This command displays the current time, the poll interval used for sending time
synchronization requests, and the current SNTP mode (i.e., unicast).
Example
Console#show sntp
Current time:
Poll interval: 60
Current
mode:
SNTP status : Enabled
SNTP server 10.1.0.11 137.82.140.80 128.250.36.2
Current server: 128.250.36.2
Console#
4-56
June 6 14:56:05 2004
unicast