  • Page 1 VERTICAL HORIZON VH-2402-L3 FAST ETHERNET SWITCH USER GUIDE 9033693-01...
  • Page 2 Notice 9033693-01...
  • Page 3 Only qualified personnel should perform installation procedures. Enterasys Networks reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made.
  • Page 4: Industry Canada Notice

    FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 5: Vcci Notice

    SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS The VH-2402-L3 24-port switch uses Class 1 Laser transceivers. Read the following safety information before installing or operating these modules. Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits.
  • Page 6 Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the switch. WARNING: FIBER OPTIC PORT SAFETY AVERTISSMENT: PORTS POUR FIBRES OPTIQUES - SÉCURITÉ...
  • Page 7: Safety Information

    WARNHINWEIS: FASEROPTIKANSCHLÜSSE - OPTISCHE SICHERHEIT SAFETY INFORMATION WICHTIGE SICHERHEITSHINWEISE (GERMANY) 1. Bitte lesen Sie diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger.
  • Page 8: Program License Agreement

    You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Enterasys. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program.
  • Page 9 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Product is considered commercial computer software in accordance with DFARS section 227.7202-3 and its successors, and use, duplication, or disclosure by the...
  • Page 10: Declaration Of Conformity

    European Representative Address: Enterasys Networks Ltd. Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC Equipment Type/Environment: Networking Equipment, for Enterasys Networks, Inc. declares that the equipment packaged with this notice 9033693-01 Manufacturer’s Name: Enterasys Networks, Inc. conforms to the above directives.
  • Page 11: Table Of Contents

    Conventions ... 13 Organization... 15 PRODUCT OVERVIEW ... 16 Description... 16 Layer 3 Switching ... 16 The Functions of a Layer 3 Switch ... 18 Features... 19 Ports ... 19 Performance Features... 20 Layer 2 Features ... 20 Layer 3 Switch Features ... 22 Traffic Classification and Prioritization...
  • Page 12 Power on... 38 Power Failure... 39 3. CONNECTING THE SWITCH ... 40 Switch to End Node ... 40 Switch to Hub or Switch ... 41 10BASE-T Device ... 42 100BASE-TX Device ... 42 APPENDIX A. TECHNICAL SPECIFICATIONS ... 43 APPENDIX B. FLOW CONTROL... 46 APPENDIX C.
  • Page 13: Preface

    Preface Purpose This guide provides information about the features and applications of the Enterasys Networks Vertical Horizon VH-2402-L3 layer 3 switch. Audience This guide is intended for Ethernet Local Area Network (LAN) administrators and Management Information Systems (MIS) personnel with the following...
  • Page 14 A caution indicates the possibility of equipment damage Keyboard Entries This guide uses the following conventions for keyboard entries: When you read “enter”, type the text and press the [Enter] key. Example: Enter the Gateway IP address and press the [Enter] key. When you read “select”, highlight the menu item and press the [Enter] key.
  • Page 15: Organization

    Organization Chapter 1. Product Overview: Describes the features of the switch, front and rear panel components and application examples. Chapter 2. Installation: Describes the content of your switch shipment, lists site requirements, and provides mounting instructions. Instructions for making connections and powering up the switch are provided as well.
  • Page 16: Product Overview

    Feature Summaries Application Example Description This installation guide describes Enterasys Networks’ Vertical Horizon VH-2402-L3 Fast Ethernet switch. The switch provides 24 10Base-T/100Base-TX ports, plus one slot for optional slide-in 1000Base-SX 1000Base-T and GBIC modules. The switch features a built in SNMP-based Management agent.
  • Page 17 Where a traditional router would have one, or at best a few, Fast Ethernet ports, the VH-2402-L3 Layer 3 switch has 24 Fast Ethernet ports and optionally, 2 Gigabit Ethernet ports. Where a traditional router would have one or two high-speed serial WAN...
  • Page 18: The Functions Of A Layer 3 Switch

    Attempts to make software- based routers forward packets more quickly were inadequate. A layer 3 switch does everything to a packet that a traditional router does: Determines forwarding path based on Layer 3 information...
  • Page 19: Features

    Updates forwarding statistics in the Management Information Base Applies security controls A Layer 3 switch can be placed anywhere within a network core or backbone, easily and cost-effectively replacing the traditional collapsed backbone router. The VH-2402-L3 Layer 3 switch communicates with a WAN router using a standard Ethernet/Fast Ethernet port.
  • Page 20: Performance Features

    1000BASE-SX, , 1000BASE-T, or GBIC Gigabit Ethernet module. RS-232 DCE Diagnostic port (console port) for setting up and managing the Switch via a connection to a console terminal or PC using a terminal emulation program. Performance Features Layer 2 Features 8.8 Gbps switching fabric capacity...
  • Page 21 IEEE 802.3ab compliant for 1000BASE-T (Copper) Gigabit ports (optional module). Data forwarding rate 14,880 pps per port at 100% of wire-speed for 10Mbps speed. Data forwarding rate 148,800 pps per port at 100% of wire-speed for 100Mbps speed. Data filtering rate eliminates all error packets, runts, etc. at 14,880 pps per port at 100% of wire-speed for 10Mbps speed.
  • Page 22: Layer 3 Switch Features

    Layer 3 Switch Features Wire speed IP forwarding. Hardware-based Layer 3 IP switching. IP packet forwarding rate of 6.6 Mpps. 2K active IP address entry table per device. Supports RIP – (Routing Information Protocol) version I and II. Supports IP version 4.
  • Page 23: Management

    Management RS-232 console port for out-of-band network management via a console terminal or PC. Spanning Tree Algorithm Protocol for creation of alternative backup paths and prevention of network loops. SNMP v.1 Agent. Fully configurable either in-band or out-of-band control via SNMP based software. Flash memory for software upgrades.
  • Page 24: Optional Redundant Power Supply

    DCHP Relay Agent. Password enabled. Optional Redundant Power Supply The VH-2402-L3, 24+2 Fast Ethernet Layer 3 Switch supports the optional Redundant Power Supply to provide automatic power supply monitoring and switchover to a redundant power supply (located in the chassis of the Redundant Power Supply) in case of a failure in the VH-2402-L3’s internal power supply.
  • Page 25: Front Panel

    , or a 2-port GBIC-based Gigabit Ethernet module. One switched MDI-X/MDI-II Uplink port that can be used to connect a straight-through cable or a crossed cable to a normal (non-Uplink) port on a switch or hub. This port is identical to the other 23 ports except for the ability to use a crossed or a straight- through cable.
  • Page 26: Rear Panel

    Rear Panel The rear panel of the switch consists of a slot for the optional Redundant Power Supply and an AC power connector. Figure 1-2. Rear panel view of the Switch The AC power connector is a standard three-pronged connector that supports the power cord. Plug-in the...
  • Page 27: Optional Plug-In Modules

    Optional Plug-in Modules The VH-2402-L3 24+2-port Fast Ethernet Layer 3 Switch is able to accommodate a range of plug-in modules in order to increase functionality and performance. 1000BASE-T Module Figure 1-5. 1000BASE-TX two-port module Front-panel module.
  • Page 28: 1000Base-Sx Fiber Module

    1000BASE-SX Fiber Module Figure 1-6. 1000BASE-SX two-port module Front-panel module. Connects to 1000BASE-SX devices at full-duplex. Supports multi-mode fiber-optic cable connections of up to 412 meters in half-duplex or 2 km in full- duplex mode. GBIC Two-Port Module Front-panel module. Connects to GBIC devices at full duplex only.
  • Page 29: Led Indicators

    A local console is a terminal or a workstation running a terminal emulation program that is connected directly to the switch via the RS-232 console port on the front of the switch. A console connection is referred to as an...
  • Page 30 So, the console can be used to set up and manage the switch even if the network is down. Local console management uses the terminal connection to operate the console program built-in to the switch.
  • Page 31 Spanning Tree Protocol The VH-2402-L3 switch complies with the IEEE 802.1D Spanning Tree Protocol standard and allows for the blocking of links between switches that form loops within the network.
  • Page 32 The VH-2402-L3 supports 6 Port Trunking groups, which may include from 2 to 8 switch ports each, except for a Gigabit Port Trunking group which consists of the 2 (optional) Gigabit Ethernet ports of the front panel. These ports are the two 1000BASE-SX, or GBIC ports contained in a front-panel mounted module.
  • Page 33: Factory Defaults

    However, with the advent of VLANs, switches are now able to limit broadcast domains better and cheaper than routers. The VH-2402-L3 switch has broadcast sensors and filters built into each port to control broadcast storms. IP Routing IP is responsible for getting packets to the destination specified in the destination address.
  • Page 34 BootP service TFTP server IP address IGMP time out IGMP capture state Partition mode Address table lock Device HOL Port HOL Console time out User name Password Device STP Port STP Port enable Bridge max age Bridge hello time Bridge forward delay Bridge priority Port STP cost Port STP priority...
  • Page 35: Installation

    Mirror src port <->target port Mirror 2. Installation Inspecting Your Shipment Open the shipping carton of the Switch and carefully unpack its contents. The carton should contain the following items: One VH-2402-L3 24+2-port Fast Ethernet Layer 3 Switch 9033693-01 Disable...
  • Page 36: Installation

    Four rubber feet with adhesive backing ESD wrist strap One AC power cord Product documentation If any item is found missing or damaged, please contact your local Enterasys Sales Representative for replacement. Installation Use the following guidelines when choosing a place to install the Switch: The surface must support at least 3 kg.
  • Page 37: Rack Installation

    (one on each side) and secure them with the screws provided. Figure 2- 2A. Attaching the mounting brackets to the switch Then, use the screws provided with the equipment rack to mount the switch on the rack.
  • Page 38: Power On

    Power on The VH-2402-L3 switch can be used with AC power supply 100-240 VAC, 50 - 60 Hz. The power switch is located at the rear of the unit adjacent to the AC power connector and the system fan. The switch’s power...
  • Page 39: Power Failure

    After approximately 20 seconds, the LED will light again to indicate the switch is in a ready state. The RDP in use LED When link with redundant power supply, the “RDP in use” LED will blink in orange. The 100M LED indicator may remain ON or OFF depending on the transmission speed.
  • Page 40: Connecting The Switch

    VH-2402-L3 or to either of the two 100BASE-TX ports on the front-panel module that came preinstalled on the switch. Port 1x can be used as an uplink port to connect to another switch using either a crossed or a straight-through cable.
  • Page 41: Switch To Hub Or Switch

    If the other switch or hub contains an unused Uplink port, we suggest connecting the other device’s Uplink (MDI-II) port to any of the switch’s (MDI-X) ports (1x - 22x, or one of the 100BASE-TX module ports) using a normal straight-through cable, as shown below.
  • Page 42: 10Base-T Device

    If the other device does not have an unused Uplink port, make the connection with a normal straight- through cable from the Uplink port on the switch to any normal crossed port on the hub. Alternatively, if you have a crossover cable you can save the Uplink ports for other connections and make this one from a crossed port to another crossed port.
  • Page 43: Appendix A. Technical Specifications

    Appendix A. Technical Specifications Standards: Protocols: Data Transfer Rates: Ethernet Fast Ethernet Gigabit Ethernet Topology: General IEEE 802.3 10BASE-T Ethernet IEEE 802.3u 100BASE-TX Fast Ethernet IEEE 802.3z 1000BASE-SX Gigabit Ethernet IEEE 802.1 P/Q VLAN IEEE 802.3x Full-duplex Flow Control ANSI/IEEE 802.3 f auto-negotiation CSMA/CD Half-duplex Full-duplex...
  • Page 44: Physical And Environmental

    Network Cables: 10BASE-T: 100BASE-TX: Fiber Optic: Number of Ports: AC inputs: Power Consumption: DC fans: Operating Temperature: Storage Temperature: Humidity: Dimensions: Weight: EMI: 9033693-01 General (Cont’d) 2-pair UTP Cat. 3,4,5 (100 m) EIA/TIA- 568 100-ohm STP (100 m) 2-pair UTP Cat. 5 (100 m) EIA/TIA-568 100-ohm STP (100 m) IEC 793-2:1992 Type A1a - 50/125um multimode...
  • Page 45 Safety: Transmission RAM Buffer: Filtering Address Packet Filtering/ Forwarding Rate: MAC Address Learning: Forwarding Table Age Time: 9033693-01 General (Cont’d) UL, CSA, CE Mark, TUV/GS UL 1950 & CSA22.2 No 950, IEC 950 (CB), TUV (EN60950) Performance Store-and-forward Method: 16 MB per device 8K MAC address per device Table: Full-wire speed for all...
  • Page 46: Appendix B. Flow Control

    In this example, large amounts of data are being sent from Workstation A (connected to port X) and other ports on the switch to Workstation B (connected to port Y).The queue on port Y starts filling up with data until it reaches a determined threshold.
  • Page 47 Flow control is configurable per port in the Port Configuration Menu of the console menus, using the on-board Web agent, or via SNMP. 9033693-01...
  • Page 48: Appendix C. Acronyms And Abbreviations

    Appendix C. Acronyms and Abbreviations Term 10Base-T 100Base-TX 100Base-FX 1000Base-SX 1000Base-LX ANSI BootP CAT5 CSMA/CD HTTP ICMP IEEE Definition 10 Mbps twisted-pair Ethernet 100 Mbps twisted-pair Fast Ethernet 100 Mbps fiber option Fast Ethernet 1000 Mbps fiber option short- wavelength Gigabit Ethernet 1000 Mbps fiber option long-wavelength Gigabit Ethernet American National Standards Institute...
  • Page 49 RMON SNMP TCP/IP TFTP VLAN 9033693-01 Request for Comment Remote Monitoring Receive Data.38 Acronyms & Abbreviations VH-2402-L3 Simple Network Management Protocol Transmission Control Protocol/Internet Protocol Trivial File Transfer Protocol Transmit Data Unshielded Twisted Pair Virtual LAN...
  • Page 50: Index

    Index 1000BASE-SX Fiber Module 1000BASE-T Module .. 27 100BASE-TX Device .. 41 10BASE-T Device ... 41 AC inputs ... 43 AC power cord ... 35 Auto polarity detection 20 auto-negotiate ... 19 Bridge MIB (RFC 1493) broadcast domains... 31 Broadcast storms ... 32 console port...
  • Page 51 RS-232 ... 20 security... 32 .. 44 Spanning Tree Algorithm Storage Temperature.. 43 Store and forward... 20 Switch to End Node ... 39 Switch to Hub ... 40 Transmission Methods 44 Uplink ... 25, 40 VLANs ... 31 Weight ... 43...