Activation
Mode
Hold down the recessed RESET button while
applying power to the unit.
NOTE:
After a boot code reset, update
the unit firmware to the latest version.
Do not operate the firmware version
that results from the boot code reset.
If you want to use the factory default
firmware, upload that version again (see
Updating the NAVigator firmware
on page 93 for details on uploading
firmware).
Hold the RESET button for approximately
6 seconds, until the RESET LED blinks twice
(once at 3 seconds and again at 6 seconds).
Then momentarily press RESET within
1 second.
Hold the RESET button for approximately 9
seconds, until the RESET LED blinks three
times (once at 3 seconds, again at 6 seconds,
and then again at 9 seconds). Then
momentarily press RESET within 1 second.
NOTE:
Full factory reset reverts the
factory-configured username to admin
and password to extron.
Performing Factory and IP Resets
Perform resets of the unit as follows (see figure 6):
1. Use a small screwdriver to press and hold the rear panel RESET button until the rear panel RESET LED blinks
either:
•
Twice, for an IP settings reset
•
Three times for an absolute (factory) reset
Press and hold
the Reset button.
IP Settings
Reset
Press and hold
the Reset button.
Factory
Reset
Figure 6.
2. Release the RESET button and then immediately press and release the RESET button again. Nothing happens
if you do not momentarily press RESET within 1 second.
Reset Mode Comparison and Summary
The unit reverts to the factory default firmware. All user files
and settings, such as IP settings, are maintained.
NOTE
Resets all the IP settings without affecting the device
configuration. Reset IP settings:
The RESET LED blinks three times in succession during the reset.
Does everything Reset network settings does:
The RESET LED blinks four times in succession during the reset.
Reset LED blinks twice.
6 seconds
RESET
Reset LED blinks
three times.
9 seconds
RESET
Resets
Result
:
If you do not want to update firmware, or you
performed a mode 1 reset by mistake, cycle power
to the unit to return to the firmware version that was
running before the mode 1 reset (see
page 127 to find the firmware version).
•
Enables ARP capability.
•
Sets the IP address, subnet address, gateway address,
and port mapping to the factory default.
•
Sets the Multicast IP, stream number and device name
to the factory default.
•
Turns DHCP on.
•
Resets all settings with the exception of factory
firmware.
•
Resets all IP options.
•
Removes all files from the unit.
•
Removes the initial serial number passwords and sets
them to extron.
Release, then immediately
press and release again.
Release, then immediately
press and release again.
NAVigator System Manager • Installation and Basic Operation
Purpose and Notes
Reset to factory firmware
to return return the unit to
the factory default
firmware version if
incompatibility issues arise
with user-loaded firmware.
About Page
on
Enables you to set IP
address information using
ARP and the MAC
address.
Full factory reset is usefuif