Page 1
User Guide TouchLink ® TLP Pro 725C Series TouchLink Pro Touchpanel Control Systems 68-3319-01 Rev. B 01 19...
Page 2
Safety Instructions Safety Instructions • English Istruzioni di sicurezza • Italiano AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad This symbol, , when used on the product, is intended to WARNING avvertire l’utente della presenza di tensione non isolata pericolosa alert the user of the presence of uninsulated dangerous voltage within the all’interno del contenitore del prodotto che può...
Page 4
FCC Class B Notice NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Page 5
Class 1 Laser Product Any service to this product must be carried out by Extron Electronics and its qualified service personnel. CAUTION: Using controls, making adjustments, or performing procedures in a manner other than what is specified herein may result in hazardous radiation exposure.
Page 6
Compliance IC Canada, Industry Canada (IC) Notices CAN ICES-3 (B)/NMB-3(B) This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Page 7
IC conformité Canada, avis d’Industry Canada (IC) CAN ICES-3 (B)/NMB-3(B) Cet appareil est conforme aux normes des cahiers des charges sur les normes radioélectriques (CNR) de l’ISDE applicables aux appareils exempts de licence. Son utilisation est subordonnée aux deux conditions suivantes : (1) Cet appareil ne doit provoquer aucune interférence, et (2) cet appareil doit accepter toute interférence, y compris l’interférence susceptible de compromettre son fonctionnement.
Page 8
Conventions Used in this Guide Notifications In this user guide, the following are used: WARNING: Potential risk of severe injury or death. AVERTISSEMENT : Risque potentiel de blessure grave ou de mort. CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure.
Introduction This guide describes the function, installation, and operation of the Extron Touchlink Pro Touchpanels: TLP Pro 725C — 7 inch TouchLink Pro Touchpanels with Series/2 Cable Cubby • TLP Pro 725C NC — a streamlined version of the TLP Pro 725C, with a set of features •...
Page 12
Patented modular design for fast assembly and serviceability — AV connectivity can • be installed or serviced from the top of the enclosure after the enclosure is installed. Series/2 Cable Access Enclosure design offers easy access to AV, data, and power •...
Application Diagram Laptops HDMI Extron COM 1 COM 2 DIGITAL I/O HDMI IPCP PRO 250 IPCP Pro 250 Tx Rx RTS CTS Tx Rx POWER RELAYS eBUS IR/S --A MAX V C G +V + S - S G IP Link Pro Audio PWR OUT = 6W Control Processor...
Installation Overview This section provides an overview of the installation process. Follow the links for a more detailed explanation of each step. Before starting to install the TLP Pro 725C, download and install the latest versions of the following software: GUI Designer —...
Page 15
Mount and cable the units: ATTENTION: Do not power on the touchpanels or control processors until you have read the • Attention about Power over Ethernet (PoE) power supplies (see page 17). Ne branchez pas les écrans tactiles ou les processeurs de contrôle avant d’avoir lu •...
Mounting There are several options for mounting both the TLP Pro 725C. Visit the Extron website (www. extron.com) for a complete list. This section outlines the various options for: Planning • Tools Required for Installation • Included Parts • Ensuring Adequate Under-table Clearance for Retractors •...
Tools Required for Installation The following tools are required for installation and must be provided by the installer: Phillips Screw Driver Tape Measure Safety Glasses 1/4" Hex Nut Driver Marking Pen Vacuum Cleaner Figure 2. Tools Required to Install the TLP Pro 725C Included Parts Open the shipping container and verify that the following parts are present: 8-cable Cable...
Ensuring Adequate Under-table Clearance for Retractors Retractors are optional accessories for handling cables with the TLP Pro 725C. If you are using retractors, ensure that there is sufficient room beneath the table to accommodate them. Horizontal mounting provides maximum legroom and protects the retractors from accidental •...
Cutting the Table Cut-out Dimensions There are three methods of making the hole for the TLP Pro 725C (see “Cutting the Surface” below): If using a Hand router and template (see the next page) you should purchase the • 7" TouchLink Pro and TouchLink routing template, part number 70-980-01 (available at www.extron.com).
Hand router and template Recommended method — use the 7" TouchLink Pro and TouchLink routing template, part number 70-980-01, which is available at www.extron.com. Follow the instructions provided in the Routing Template User Guide, available at www.extron.com. NOTE: The metal router guide must be purchased separately. It is reusable and should not be discarded when the installation is complete.
Preparing AAP Modules If required, AAPs must be purchased separately. Go to www.extron.com to see the full range of AAPs that are available. Secure up to three single space AAPs in the AAP Frame, using the #4-40 nut with captive washer provided with the AAP (figure 8, If required, fill any unused spaces with blank AAP plates.
Installing Modules The TLP Pro 725C has three triple spaces available for installing modules. If cable retractors are installed, they should occupy one of the end spaces. There is no preferred order for the power module, cable pass-through module, or AAP module. If required, AAPs, retractors, and power modules must be purchased separately.
Secure the module in position with #6-32 Phillips head screws and star washers (see figure , on the previous page). This is especially important for the power modules (see “Special Considerations for Power Modules” below). NOTE: Different countries require different power adapters. See www.extron.com select a power module that is suitable for your location.
Mounting the TLP Pro 725C Enclosure Once the enclosure is permanently mounted, the button (see figure , on Menu page 17) and the LAN/PoE port ( ) are under the table and may be difficult to access. Before mounting the touchpanel, you should use the setup menu to configure the touchpanel (see Setup Menu on page 19) and connect an Ethernet cable to the...
Installing Cable Retractors (Optional) Extron cable retractors retract and neatly store cables in Cable Cubby systems, preventing them from tangling underneath the table. Retractor kits are available for many cable types. Up to six retractors can be installed in the TLP Pro 725C enclosure (three on each end). They are not provided with the touchpanel and must be purchased separately.
Panel Features This section describes the TLP Pro touchpanels: TLP Pro 725C Front Panel and Enclosure Features • TLP Pro 725C Base Features • TLP Pro 725C Front Panel and Enclosure Features Figure 12 shows the TLP Pro 725C front panel and the Cable Cubby enclosure. LCD screen Motion sensor Communication LED...
Activation Switch (see figure 12 on the previous page) – the left side of the lid hinge mechanism contains a switch. When the lid is closed, the switch sends the screen into sleep mode. When the lid is opened, the screen display is restored and active. When the lid is shut, the screen is not activated by motion near the touchpanel.
Page 28
ATTENTION: The touchpanels are intended for connection to a Power over Ethernet circuit for • intra-building use only and are considered to be part of a Network Environment 0 per IEC TR62101. Les écrans tactiles sont conçus pour une connexion à un circuit PoE pour une •...
On-screen Menus On-screen menus allow initial configuration of the touchpanels. Setup Menu To open the setup menu, use a screw driver with a fine blade to press the button. The Menu figure Menu button is located on the base of the TLP Pro 725C (see on page 17).
Network Verify with your network administrator whether the IP address for the touchpanel is assigned by Dynamic Host Configuration Protocol (DHCP) or set manually. If they are set manually, you need to obtain an IP address, a subnet mask, a gateway address, and a Domain Name Server (DNS) from the network administrator.
Page 31
If DHCP is disabled, set the unit IP address, subnet mask, gateway address, and DNS server address. Press the button for the address to be edited. A screen opens, showing the address and a numerical keypad. IP Address Clear 1 9 2 1 6 8 2 5 4 2 5 1...
Display Press the button in the navigation panel at the top of the screen to open the Display Display screen. Display Audio Advanced Exit Status Network Auto Brightness Sleep Timer LCD Brightness Minutes Wake on Motion Figure 19. Display Screen Display screen allows you to set the Sleep Timer...
Audio Press the button in the navigation panel at the top of the screen to open the Audio Audio screen. Display Audio Advanced Exit Status Network Master Click Sound Figure 20. Audio Screen On the Audio screen, use the slider controls to adjust the Master Click , and...
Advanced Press the button in the navigation panel at the top of the screen to open the Advanced Advanced screen. Display Audio Advanced Exit Status Network System GUI Project Touchpanel Name: TLP-AB-CD-EF Name: Jet Video Conference System Controller Name: IPCP 505 - North Hall Resolution: 1024x600 Controller IP:...
Configuration Software This section of the user guide provides information about: Configuration Software • Touchpanel Web Page • Updating the Firmware • Configuration Software Designing a graphical user interface (GUI) for the TouchLink Pro touchpanel takes two steps: Design the layout of the screen text and graphics using GUI Designer. Assign functions to the text and graphics using Global Configurator Plus and Professional.
Installing GUI Designer, Global Configurator, Toolbelt, and Global Scripter NOTES: GUI Designer is used to design the layout of the touchpanel screen • Global Configurator Plus and Professional is used to configure Extron Ethernet-enabled • control products. Toolbelt is used to manage and troubleshoot Extron Pro series control products. •...
Clicking directly on the product name takes you to the product page, which provides more information about the software. Click and, on the new page, provide the Download information requested. An executable file ( ) is placed in your default folder.
Touchpanel Web Page There is a single, read-only page that provides general and network information about the unit (see figure 16, below). It also allows you to upgrade the unit firmware. Use the Setup Menu (see page 19) or Toolbelt to configure the touchpanel network settings. To access the touchpanel default web page, enter the IP address of the touchpanel into the web browser of a PC connected to the same subnet.
Updating the Firmware Firmware for the TLP Pro 725 series touchpanels can be upgraded using Toolbelt or the touchpanel web page. Before starting, consult your IT team and ensure that the touchpanel has a unique IP address. Downloading Firmware Power on a computer that is connected to the same network as the touchpanel. Go to www.extron.com, click (see figure 27, ) and then click...
Reference Material This section describes: Network Port Requirements and Licensed Third-Party Software • Reset Modes • Network Port Requirements and Licensed Third-Party Software For information about network port requirements and licensed third-party software for the touchpanels described in this guide, please refer to the Pro Series Control Product Network Ports and Licenses Guide, which is available at www.extron.com.
Reset All IP Settings This mode resets all IP settings to factory defaults. Activation To reset all IP settings: Hold down the button for about 6 seconds until the Power LED blinks twice (once at Reset 3 seconds and again at 6 seconds). Release and press Reset momentarily (for <1 second) within 1 second.
Page 42
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Need help?
Do you have a question about the TouchLink TLP Pro 725C Series and is the answer not in the manual?
Questions and answers