Extron electronics TLP Pro 1022M User Manual

Extron electronics TLP Pro 1022M User Manual

Touchlink pro series touchpanel control systems
Hide thumbs Also See for TLP Pro 1022M:

Advertisement

User Guide
TouchLink
®
TLP Pro 1022 Series
TouchLink Pro Touchpanel Control Systems
68-2405-02 Rev. A
07 16

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics TLP Pro 1022M

  • Page 1 User Guide TouchLink ® TLP Pro 1022 Series TouchLink Pro Touchpanel Control Systems 68-2405-02 Rev. A 07 16...
  • Page 2 Safety Instructions Istruzioni di sicurezza • Italiano Safety Instructions • English WARNING: This symbol, , when used on the product, is intended AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad to alert the user of the presence of uninsulated dangerous voltage avvertire l’utente della presenza di tensione non isolata pericolosa within the product’s enclosure that may present a risk of electric shock.
  • Page 3 All trademarks mentioned in this guide are the properties of their respective owners. The following registered trademarks®, registered service marks(SM), and trademarks(TM) are the property of RGB Systems, Inc. or Extron Electronics (see the current list of trademarks on the Terms of Use page at www.extron.com):...
  • Page 4 FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
  • Page 5 Conventions Used in this Guide Notifications In this user guide, the following are used: Potential risk of severe injury or death. WARNING: AVERTISSEMENT : Risque potentiel de blessure grave ou de mort. CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure.
  • Page 7: Table Of Contents

    Contents Introduction Mounting ............1 ............... 18 About the TLP Pro 1022 Series .......1 Mounting the TLP Pro 1022M .......18 Features ..............1 Wall Mounting ...........18 Application Diagram ..........2 Furniture Mounting ..........20 Mounting the TLP Pro 1022T ........21 Removing the Base and Back Covers ....21 Installation Overview ...........
  • Page 8 TLP Pro 1022 Series • Contents viii...
  • Page 9: Introduction

    Introduction This guide describes the function, installation, and operation of the Extron TLP Pro 1022M and TLP Pro 1022T Touchlink Pro Touchpanels: Unless otherwise stated, the terms “touchpanel,” “TLP Pro,” “TLP Pro 1022,” or “TLP Pro 1022 eries” refer to both models. The touchpanels are ideal for any AV applications requiring medium or large touchpanels with flexible mounting options and fully customizable interfaces.
  • Page 10: Application Diagram

    VESA FDMI Type D 75 mm mounting pattern standard can be used for VESA mounting. • Application Diagram The application diagram below shows the TLP Pro 1022M. The TLP Pro 1022T can be used in a similar configuration. Extron COM 1...
  • Page 11: Installation Overview

    Mount the units. There are several mounting options for either touchpanel (see Mounting page 18). NOTE: If you use the setup menu to configure the TLP Pro 1022M, do not mount the unit before configuring it. You need access to the rear panel button. Menu Configure the Touchpanels —...
  • Page 12: Panel Features

    Speakers Status Light Motion Sensor Light Sensor Menu Button (TLP Pro 1022M only) Capacitive Touchscreen Figure 2. TLP PRO 1022 Series Front Panels Communication LED — shows the configuration and connection status of the touchpanel: Unlit during normal operation (the touchpanel is configured and connected to an IP Link •...
  • Page 13: Rear Panel Features

    Calibration Screen (see page 13). LAN/PoE Connector— is on the back of the TLP Pro 1022M. On the TLP Pro 1022T, it is in the top of the recessed area, to the right side. NOTE: These touchpanels are shipped without a power injector. The power injector must be purchased separately.
  • Page 14 Connect a straight-through Ethernet cable to the power supply and a switch or router. This cable carries network information from the switch or router to the power supply input. A second straight-through cable carries the network information and 48 VDC from the power supply to the touchpanel.
  • Page 15 The network port has two LEDs. The green LED lights steadily to indicate that the touchpanel is connected correctly to a network. The yellow LED flashes to indicate that data is being passed to or from the touchpanel. Mounting holes (4) (TLP Pro 1022M only) (see figure 3) — for wall mounting (see Wall Mounting on page 18).
  • Page 16: On-Screen Menus

    Pressing this button applies Exit and saves any changes and closes the menu screens. In this section, the figures show the screens for the TLP Pro 1022M. The screens for the TLP Pro 1022T are similar. Status...
  • Page 17 Network Verify with your network administrator whether the IP address for the touchpanel is assigned by Dynamic Host Configuration Protocol (DHCP) or set manually. If they are set manually, you need to obtain an IP address, a subnet mask, a gateway address, and a Domain Name Server (DNS) from the network administrator.
  • Page 18: Network Screen

    If DHCP is disabled, set the unit IP address, subnet mask, gateway address, and DNS server address. Press the button for the address to be edited. A screen opens, showing the address and a numerical keypad. IP Address Clear 1 9 2 1 6 8 2 5 4 2 5 1...
  • Page 19: Display Screen

    Display Press the button in the navigation panel at the top of the screen to open the Display Display screen. Display Audio Advanced Exit Status Network Auto Brightness Sleep Timer LCD Brightness Minutes Wake on Motion Figure 9. Display Screen screen allows you to set the Display Sleep Timer...
  • Page 20: Audio Screen

    Audio Press the button in the navigation panel at the top of the screen to open the Audio Audio screen. Display Audio Advanced Exit Status Network Master Click Sound Figure 10. Audio Screen On the screen, use the slider controls to adjust the , and volume Audio...
  • Page 21: Calibration Screen

    Menu PIN The PIN setup options allow you to enable, disable, or change the setup menu PIN. The PIN is a 4-digit number. Each digit can have any value from 0-9. Select the first digit of the PIN. When selected, it is highlighted in yellow. Enter New Menu PIN Back Cancel...
  • Page 22: Configuration Software

    Configuration Software This section of the user guide provides information about: Configuration Software • TLP Pro 1022 Series Web Pages • Updating the Firmware • Configuration Software Designing a graphical user interface (GUI) for the TouchLink Pro touchpanel takes two steps: Design the layout of the screen text and graphics using GUI Designer.
  • Page 23: Installing Gui Designer, Global Configurator, And Toolbelt

    Installing GUI Designer, Global Configurator, and Toolbelt NOTE: Use GUI Designer, Global Configurator Plus and Professional, and Toolbelt to configure the TLP Pro touchpanel. GUI Designer, Global Configurator, and Toolbelt can be downloaded from www.extron.com. Select the tab ( ) and click the option ( ) in the sidebar at the left.
  • Page 24: Using The Software

    Use the Setup Menu (see page 8) or Toolbelt to configure the touchpanel network settings. Figure 16 shows the TLP Pro 1022T web page. The web page for the TLP Pro 1022M is similar. Extron Electronics ® General Status...
  • Page 25: Updating The Firmware

    Updating the Firmware Firmware for the TLP Pro 1022 series can be upgraded using Toolbelt or the touchpanel web page. Before starting, consult your IT team and ensure that the touchpanel has a unique IP address. Downloading Firmware Power on a computer that is connected to the same network as the touchpanel. On the Extron website, click in the menu bar along the top of the page (see Download...
  • Page 26: Mounting

    The touchpanels can be mounted into drywall. ATTENTION: Do not install the TLP Pro 1022M in a fire resistant rated wall or partition assembly. • Ne pas installer le TLP Pro 1022M dans un mur résistant au feu ou une cloison.
  • Page 27 Touch Panel. Figure 19. Wall Mounting the TLP Pro 1022M with the BB 710M Cut a hole in the drywall, 7.70 inches (19.56 cm) wide x 6.00 inches (15.24 cm) high, and install the BB 710M, as described in the BB 710M Installation Guide (see www.extron.com).
  • Page 28: Furniture Mounting

    3-8 on the previous page. Furniture Mounting The TLP Pro 1022M can be mounted into the surface of a lectern or other furniture by following Mounting without a wall box, above. the same procedure as wall Download the cut-out template for your touchpanel from www.extron.com. Print it at 100% (no scaling).
  • Page 29: Mounting The Tlp Pro 1022T

    Mounting the TLP Pro 1022T The TLP Pro 1022T comes with a stand that allows it to be placed on any suitable flat surface. www.extron.com for a range of available optional mounting kits. The kits must be purchased separately. Follow the installation instructions provided with the kit. Removing the Base and Back Covers To attach cables and to mount the TLP Pro 1022T with the SMA-1 swivel mount adapter...
  • Page 30: Desktop Mounting

    Desktop Mounting Placement without a mounting kit The TLP Pro 1022T has a stand that allows it to be placed on a desktop. The unit can be secured to the desktop using screws. Figure 22. TLP Pro 1022T Base Under the table top, mark the location of two mounting holes, 3.07 inches (78 mm) apart. Drill two holes through the table top from underneath.
  • Page 31: Reference Material

    Reference Material This section describes: Network Port Requirements and Licensed Third-Party Software Used by the • Touchpanels Reset Modes • Network Port Requirements and Licensed Third-Party Software Used by the Touchpanels For information about network port requirements and licensed third-party software for the TLP Pro 1022 series touchpanels, please refer to the Pro Series Control Product Network Ports and Licenses Guide, which is available at www.extron.com.
  • Page 32: Reset All Ip Settings

    Result The unit reverts to factory-installed firmware. Event scripting does not start if the unit is powered on in this mode. All user files and settings such as drivers, adjustments, and IP settings are maintained. NOTE: To return the unit to the firmware version that was running prior to the reset, cycle power to the unit.
  • Page 33 Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.