IBM System/360 2050 Maintenance Manual page 117

Processing unit
Table of Contents

Advertisement

s,o,
1
Abbreviation
Name
Digit 4-Q;glt
S
Oigih 6,7,8,9
Comments
+00
HB
Holt and Branch
Not used
Branch address
Next instruction from PR
6-9.
-00
HP
Holt and Proc.e9d
Not used
Not used
Next instruction from IC.
+01
B
Branch
Not used
Branch address
Unconditional branch without halt;
next instruction from
PR 6-9.
-01
NOP
No Operation
Not used
Not used
Not instruction from IC.
+02
BLX
Branch and Lood Location in Index Word
Incle• Word for storing IC
Branch address
Contents
of
IC Cl"e stored in index
word, positions
2-5.
+03
CD
Compare Storage to Digit
Value compared
P01ition to be compared
Address
of
data
Tums on high, low, or equal
indieator.
-03
Sign Control
Sign value
Operation:
CompCl'e opsations turn on high,
CSA
Compare Sign to Alpha
3,6,
or
9
0. Compare
Addreu
of
data for operations
low, or equal indicator:
CSM
Compare Sign to Minus
1. Molce
0-1
CSP
Compare Sign to Plus
2. Sign change sense
Not used for operations 2 and 3
Highost
+9999999999
MSA
Make Sign Alpha
3. Sign chonge stop
-+0000000000
MSM
Make Sign Min"'
4. Sign change test
Branch address for opwation 4
-0000000000
MSP
Make Sign Plus
-9999999999
@9999999999
SMSC
Operation 2
Lowest
@0000000000
HMSC
Operation 3
BSC
Operation 4
+08
-OB
Unemulated
+09
Operations
-09
+10
BZI
Branch if Zero in Accumulator 1
Not used
Branch address
Sign is ignored.
-10
BMl
Brcrich if Minus in Accumulator 1
Not
used
Bronc h address
Contents are ignored.
+11
BVl
Branch if Overflow in Accumulator 1
Not used
Branch oddr9n
IF overflow indicator is on, brmch
and turn
it off.
-11
ZSTl
Zero 5toroge
and
Store Accumulator 1
Field definition
Adch11 of data
•12
sn
$tore Accumu lotor 1
Field definition
Address of data
-12
STDl
Store Digits From Accumulator 1 and
Field definition
Addre11
of
data
Ignore Sign
+13
ZAl
Zero Accumulator 1 and Add
Field definition
Addre11
of data
-13
ZSl
Zero Accumulator 1 and Subtract
Field definition
Addreu
of
data
+14
Al
Add to Accumulator 1
Field definition
Addre•
of
doto
-14
Sl
Subtract from Accumulator 1
Field definition
Addreu
of data
+15
Cl
Compare Accumulator 1
to
Storage
Field definition
Addreu of doto
Sets high, low, or equal indicator,
-15
CA
Compare Abtolute in Accumulator 1 to
Field definition
Address
of data
Sets high, IOW", or equal indicator.
Abiolute in Storage
+16
ZAA
Zero Accumulator 1 and Acid Absolute
Field definition
Address of data
-16
Z5A
Zero Accumulator 1 and Subtract Abiolute
Field definition
Addr••
of
doto
+17
AA
Add Absolute to Accumulator 1
Field definition
Address
of
data
-17
SA
Subtract Absolute from Accumulator 1
Field definition
Addr..,
of data
+18
ASl
Add to Storage
r-
Accumulator 1
Field definition
Addre11 of data
-18
SSI
Subtract Accumulator 1 from Storage
Field definition
Addre11
of data
+19
AASl
Add to Absolute Storage from Accumulator
Field definition
Addrou
of data
1
+20
BZ2
Branch if Zero in Accumulator 2
Not used
Branch oddr.,
Sign is ignored.
-20
BM2
Branch
if
Minus in Accumulator 2
Not
used
Branch oddrou
Contents are ignored.
+21
BV2
Branch if Overflow in Accumulator 2
Not used
8rC"a"tch addr•s
If overflow indicator is on, branch
and 1 ... n If off.
-21
ZST2
Zero Storage and Store Accumulator 2
Field definition
Address of data
+22
ST2
Store Accumulator 2
Field definiticn
Addro11
of data
+23
ZA2
Zero Accumulator 2 and Add
Field definition
Addroa of data
-23
ZS2
Zero Accumulator 2 and Subtract
Field definition
Addre11
of data
+24
A2
Add to Accumulator 2
Field definition
Addreu
of data
-24
S2
Subtract from Accumulator 2
Field definition
Acldr.,. of data
+25
C2
Compare Accumulator 2 to Storage
Field definition
Acidreu
of
doto
Sets high, low, or equal indicator,
+28
AS2
Add to Storage from Accumul otor 2
Field definition
Addr""
of
data
-28
SS2
Subtract Accumulator 2 from Storage
Field definition
Addrea of data
+29
AAS2
Add to Abooluto Storage
Field definition
Addr . . . . . . . .
+30
BZ3
Branch if Zero ln Accumulator 3
Not IMd
Branch oddr . .
Sign is Ignored.
-30
BM3
Branch
if
Minus in Accumulator 3
Not
used
Branch oddr•1
Contents ore ie-od.
+31
BV3
Branch if Overflow in Accumul- 3
Not
used
Branch oddr..,
If overflow indicator is on, branch
and
tum
It off.
-31
ZST3
Zero Storage and Store Accumulator 3
.Field dofiniHon
Addr.,.
of data
+32
ST3
Store Accu01UI- 3
Field definition
Addr . .
of
data
-32
STD3
Store Digits from Accumulator 3
and
Fleld cWinition
Addroa of data
Ignore Sign
FIGURE 111. EMULATED 7070;74 OPERATION CODES (PART 1 OF•)