To adjust finishing of embroidering
7-7.

Not to stand out the edge of upper thread (Upper thread lock timing)

7-7-1.
Explanation on the screen
10 Upper thread lock timing
F2
Release
Lock
Timing to open upper thread lock
[a]
Perform adjustment when the edge of upper thread remains
on the fabric after thread trimming. When the edge of upper
thread is still highly visible at A, set to B or C.
The edge of upper thread is easy to remain.
A
B
C
The edge of upper thread is hard to remain.
[b]
Timing to close upper thread lock
Perform adjustment when the edge of upper thread remains
on the fabric after thread trimming. When the edge of upper
thread is still highly visible, set to B or C.
7-7-2.
How to operate
The following is an example that remaining length of upper thread is set to "B" after start sewing.
(1)
To open screen
To select remaining length of upper thread after start of sewing
(2)
114
A
A/B/C
A
A/B/C
10 Upper thread lock timing
B
[a]
[b]
Chapter 5
Upper thread
lock
Open
Close
Edge of
upper thread