To Stop At Frame Limit (Frame Limit Setting) - TAJIMA TFMX-IIC User Manual

Table of Contents

Advertisement

To stop the machine
4-4.

To stop at Frame Limit (Frame Limit setting)

This is the setting to stop the frame at Flame Limit (movable limit position). To stop at Frame Limit, it is
necessary to be memorized the frame origin correctly by the machine. The position where the frame stops
differs in every "Frame Type". This function is not applicable for L-spec. machine.
Screen
4-4-1.
6 Frame Limit Setting
4-4-2.
How to operate
Selecting "NO" will not stop the frame at frame limit. The frame could interfere with the
peripheral part resulting in its breakage.
The following is an example that the frame is stopped at Frame Limit.
Set to main screen.
(1)
To press F1 key while pressing SET
(2)
96
NO
Stop at Frame Limit
Selecting "NO" will not display the following
message at data input.
!
CAUTION
1 Password (Functional Limit)
YES: To stop (usual setting)
NO: Not to stop
OK to move a frame to the
start point of design data ?
Chapter 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tfmx-cTwmx-cTfmxTfmxl

Table of Contents