Garmin GI 275 Installation Manual page 443

Part 23 aml stc
Hide thumbs Also See for GI 275:
Table of Contents

Advertisement

Function
Resistive Floats
(GEA 110)
Resistive Floats
(GEA 24)
CiES CC284022-
XXXX-XXX
Resistive Floats
(GEA 110)
Resistive Floats
(GEA 24)
CiES CC284022-
Fuel Quantity
XXXX-XXX
(Main & Aux) [5]
Resistive Floats
(GEA 110)
Resistive Floats
(GEA 24)
CiES CC284022-
XXXX-XXX
Resistive Floats
(GEA 110)
Resistive Floats
(GEA 24)
CiES CC284022-
XXXX-XXX
CDT
Varies
Varies
IAT
Varies
OAT
Garmin
Notes:
[1] Select the GEA 110 or GEA 24 port that the sensor is connected to in order to access the sensor configuration.
[2] Refer to Section 5.6.2 for fuel flow gauge smoothing filter and K-factor selection.
[3] Refer to Section 5.6.2 for P-lead magneto type and propeller-to-engine gear ratio selection.
[4] Available for GEA 110 only.
[5] GEA 24 EIS systems with resistive fuel probes must be configured with the 0-5 Volt sensor configuration.
[6] GI 275 software v2.42 or later must interface with GEA 110 software v2.21 and use P-Lead version 2 sensor configurations.
190-02246-10
Rev. 11
Mfr
Garmin P/N
N/A
Left/Single Tank
N/A
Left/Single Tank
N/A
Left/Single Tank
N/A
Right Tank
N/A
Right Tank
N/A
Right Tank
N/A
AUX Left/Single Tank
N/A
AUX Left/Single Tank
N/A
AUX Left/Single Tank
N/A
AUX Right Tank
N/A
AUX Right Tank
N/A
AUX Right Tank
N/A
K Type
N/A
K Type
N/A
J Type
011-00978-00
GTP 59
Description
Sensor Configuration
0-620Ohm Left Main (v1) or
0-620Ohm Single Main (v1)
0-5 Volt Left Main (v1) or
0-5 Volt Single Main (v1)
Digital (v1) or 0-5Volt (v1)
0-620Ohm Right Main (v1)
0-5 Volt Right Main (v1)
Digital (v1) or 0-5Volt (v1)
0-620Ohm Left Aux (v1) or
0-620Ohm Single Aux (v1)
0-5 Volt Left Aux (v1) or
0-5 Volt Single Aux (v1)
Digital (v1) or 0-5Volt (v1)
0-620Ohm Right Aux (v1)
0-5 Volt Right AUX (v1)
Digital (v1) or 0-5Volt (v1)
NIST ITS-90 K Type (v1) [1]
NIST ITS-90 K Type (v1) [1]
NIST ITS-90 J Type (v1) [1]
Garmin GTP 59 (v1) [1]
Authorization
Interface only
Interface only
Interface only
Interface and installation
GI 275 Part 23 AML STC Installation Manual
Page C-25

Advertisement

Table of Contents
loading