4.5.2

GSB 15 Connector Assembly

Prepare the shielded cables to be connected to the LRU in accordance with Section 4.1.1, then terminate
the cables to the LRU ground lug using the following procedure:
1. Terminate the crimped pin/socket contacts in the locking connector in accordance with the aircraft
wiring drawings.
2. Attach the locking connector to the GSB 15, paying attention to the keying and latching features of
the connector.
3. If the data transfer functionality is intended to be used, terminate the shield drain ring terminal to
the ground lug on the back of the GSB 15 unit using the 4-40 x 0.125 pan head screw. This step is
not required if the GSB 15 will be used for charging only.