Figure 5-23 Gauge Configuration Example - Garmin GI 275 Installation Manual

Part 23 aml stc
Hide thumbs Also See for GI 275:
Table of Contents

Advertisement

As an example only, the configuration of a pressure gauge is shown in Figure 5-23.
a.
d.
g.
Use the following procedure for gauge configuration:
1. Complete Table 5-57 for each gauge specified in the AFM/POH or other approved data, and refer
to Table 5-58 for additional settings.
2. Using the information gathered in step 1, configure each gauge as shown in the example in
Figure 5-23. The EIS gauge settings must accurately convey the limitations in the AFM/POH or
other approved data.
3. Use Table 5-59 as an additional guide to set the gauge ranges. When setting the gauge range, verify
the minimum and maximum values are captured within the physical markings of the gauge. It may
be necessary to adjust the minimum and maximum gauge range so that the gauge needle has a
value represented. Refer to Figure 5-24 for an example.
4. When configuring gauge ranges that include red line markings, the total gauge range must be
configured so that the pilot can identify an exceeded value if the gauge passes the redline marking.
190-02246-10
Rev. 11
b.
e.
h.

Figure 5-23 Gauge Configuration Example

c.
a.
b.
c.
d.
e.
f.
f.
g.
h.
i.
i.
GI 275 Part 23 AML STC Installation Manual
Select Gauges from the
EIS page.
Select the gauge type to be
configured.
Configure the gauge units
and Gauge Range.
Select Marks.
Select New Range to add a
range.
Configure color, range
minimum, and range
maximum. Select Enter to
confirm. Repeat as
necessary to configure
markings.
Select New Line to add a
line.
Configure line color, value,
and as a minimum or
maximum. Select Enter to
confirm. Repeat as
necessary to configure
markings.
Verify final gauge
presentation.
Page 5-65