5.4.15 Stormscope
Configure the Stormscope interface per the settings in Table 5-39.
Stormscope
Interface
WX-500
WX-500
Wired to other
Other GI 275
GI 275
5.4.16 PFD Sync
Configure PFD Sync as HSDB if interfaced to a G500/G600 TXi system via HSDB. PFD Sync allows the
TXi GDUs and GI 275 displays to sync the heading bug, course bug, and baro correction.
Interface
HSDB
5.4.17 General Purpose Discrete In
Configure the General Purpose Discrete In ports and speeds per the settings in Table 5-41.
General Purpose Discrete In
Discrete In
5.4.18 General Purpose Discrete Out
Configure the General Purpose Discrete Out ports and speeds per the settings in Table 5-42.
General Purpose Discrete Out
Discrete Out
190-02246-10
Rev. 11
Table 5-39 Stormscope Configuration Settings
Ports/Config - Settings
Table 5-40 PFD Sync Configuration Settings
Ports/Config - Settings
GDUs Installed
Table 5-41 General Purpose Discrete In Settings
Ports/Config - Settings
Audio Inhibit
Display Backup
Table 5-42 General Purpose Discrete Out Settings
Ports/Config - Settings
On Ground
Terrain Aud Actv
RS-232 RX
Port Numbers
Discrete In Lo
Discrete In Lo
Port Numbers
Discrete Out Lo
GI 275 Part 23 AML STC Installation Manual
Port Numbers
1 Thru 3
Port Numbers
1 Thru 6
5 Thru 6
1 Thru 9