Table 5-62 Fuel Quantity Calibration Settings - Garmin GI 275 Installation Manual

Part 23 aml stc
Hide thumbs Also See for GI 275:
Table of Contents

Advertisement

Setting
Gauge Max Main
Gauge Max AUX
Num Points
Procedure
190-02246-10
Rev. 11

Table 5-62 Fuel Quantity Calibration Settings

Options
Main Gauge Maximum
(0-2980 GAL)
AUX Gauge Maximum
(0-2980 GAL)
5 to 15 points
Single Main
Single AUX/Tip
Main L & R (Recom.)
AUX/Tip L & R (Recom.)
Main L
Main R
AUX/Tip L
AUX/Tip R
Notes
Set to match the maximum range from the
gauge being removed. This is configured on
the EIS → Gauges → Fuel (Main) page.
Set to match the maximum range from the
gauge being removed. This is configured
under the EIS → Gauges → Fuel (Aux).
The accuracy of the fuel quantity indication
will increase with more calibration points. It is
recommended to use at least the same
number of points as graduations on the
gauge being replaced. Refer to Section
5.7.5.1 for details.
Main L & R and Aux/Tip L & R procedures
alternate left then right calibration points to
keep the aircraft balanced. These are
recommended if the aircraft has left and right
tanks. The available options are dependent
on "Main Tank" and "Aux Tank" settings on
the Fuel page.
GI 275 Part 23 AML STC Installation Manual
Page 5-80