Transmitted Data For Servimat - Reflex Anybus CompactCom Original Operating Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Word
Word address
address
Designation
hexadecimal
decimal
#17h
23d
Warnings 1
#18h
24d
Warnings 2
#19h
25d
Warnings 3
Operating hours
#1Ah (H)
26d (H)
Pump 1 (32-bit
#1Bh (L)
27d (L)
value)
Operating hours
#1Ch (H)
28d (H)
Pump 2 (32-bit
#1Dh (L)
29d (L)
value)
Accumulated sum
#1Eh (H)
30d (H)
Water meter in litres
#1Fh (L)
31d (L)
(optional) (32-bit
value)
#20h
32d
Bus module status
Feedback, motorised
#22h
34d
ball valve 1 (current
position: 0 – 100 %)
Feedback, motorised
#23h
35d
ball valve 2 (current
position: 0 – 100 %)
System type
4 = Servitec
#21h
33d
Magcontrol
5 = Servitec
Levelcontrol
Conductivity (μs/cm)
(Only for
#26h
38d
"Conductivity
monitoring" option)
Bit addresses
170h: ---
171h: ---
172h: Pump runtime exceeded
173h: Make-up time exceeded
174h: Make-up cycles
exceeded
175h: Maximum pressure
exceeded
176h: Make-up quantity
exceeded
17Ah: Make-up valve leaking
17Bh: Power failure
17Ch: ---
17Dh: Parameter defective
17Eh: Maximum make-up
quantity exceeded
17Fh: Maintenance requested
180h: Replace battery
181h: Softening, replace
cartridge
182h: Check data logger
183h: Check bus module
184h: --
185h: ---
190h: Expansion module,
message digital input 1
191h: Expansion module,
message digital input 2
192h: Expansion module,
message digital input 3
193h: Expansion module,
message digital input 4
194h: Expansion module,
message digital input 5
195h: Expansion module,
message digital input 6
196h: Expansion module,
message digital output 6
---
---
---
200h
0 = no connection between
bus module and controller
1 = connection between bus
module and controller OK
---
---
---
---
Anybus® - CompactCom / Modbus-RTU® — 08.11.2022 - Rev. B
Word
Word address
address
Designation
hexadecimal
decimal
Software version of
the bus module
#25h
37d
(217 = V 2.17)
6.2.3

Transmitted data for Servimat

Word
Word address
address
Designation
hexadecimal
decimal
System pressure in
#10h
16d
1/100 bar
Filling level in
#11h
17d
1/100 bar
#12h
18d
Digital outputs
#13h
19d
Digital inputs
#14h
20d
Fault messages 1
#15h
21d
Fault messages 2
Transmitted data
Bit addresses
---
Bit addresses
---
---
120h: Compressor 2 or Pump
2 on
121h: Compressor 1 or Pump
1 on
122h: Overflow valve 2 open
123h: Overflow valve 1 open
124h: Make-up valve open
125h: Message: min. level
126h: Message Group alarm
(1 = OK)
130h: Feedback Pump 1
131h: Feedback Pump 2
132h: Insufficient water
switch
133h: Water meter
140h: Expansion module
fault (Option)
141h: EEPROM defective
142h: Under voltage
143h: Below minimum
pressure
144h: Low water 1
145h: Pump 1 faulty
146h: Compressor 1 faulty
147h: Pump 2 faulty
148h: Compressor 2 faulty
149h: Pressure measurement
fault
14Ah: Level measurement
fault
14Bh: longer than 4 hours in
STOP mode
14Eh: Balancing parameter
incorrect (main board)
14Fh: Communication faulty
(networking)
150h: Main circuit board fault
151h: Digital input voltage
fault
152h: Analogue input
voltage fault
153h: Input voltage ball
valve 1 fault
154h: Input voltage ball
valve 2 fault
155h: Jumper fault –
pressure
156h: Jumper fault – level
English — 27

Advertisement

Table of Contents
loading

Table of Contents