Chapter 5 Service Commands
Testing the Library
Performing a Service
Calibration
80
Procedure (continued)
Select all desired test options:
3
To swap cartridges randomly, press the Random button.
If you do not press this button, cartridges are swapped
sequentially from the first bin or drive.
To have the library read the bar code as it swaps each cartridge,
press the Use Barcodes button.
To have the test run continuously until aborted, press the
Continuous button. Otherwise, enter the number of times you
want the test to run into the # of Runs box.
When you have selected the test and all test options, press the
4
Execute button.
The GUI displays a "Command In Progress" screen.
To cancel the system test, press the Abort button.
Note: If you selected the Continuous option in step 3, you must press
the Abort button to stop the test.
The Service Calibrate command autocalibrates the library (the tape
drives, the cartridge bins, and the load port) and saves the target
5
locations as a baseline for all subsequent calibration procedures.
Note: Before performing a service calibration, remove all tape cartridges
from the library.
To perform a service calibration, press the Calibrate Library button on
the Service screen. The GUI displays a "Command In Progress" screen
during the calibration process.
To cancel the calibration process, press the Abort button.
ATL P1000 Series User's Guide