Chapter 2 Installing the P1000 Library
Site Requirements
Figure 11 AC Power
Receptacle
Environmental
Requirements
16
Power Inlet
The power inlet is an IEC-320 connector (see figure 11). For
international applications, replace the power cord with a harmonized
2
3 x 1.0 mm
power cord approved by the country where used.
Ground
Line
Rack Current Rating Consideration
Consider the current rating of the rack before installing more than one
P1000 library. The P1000 library is rated 6A/3A (120V/230V). This
means that no more than two libraries can be installed in a typical
15A/120V rack.
If other equipment is installed in the rack, determine the total current
rating of all the equipment before adding the P1000 library to the rack.
Grounding
The P1000 must be connected to a grounded power outlet. If the
library is rack-mounted, the rack must also be grounded.
Temperature
The rack temperature should be less than 32 C.
The installation site (stand-alone library) or the interior of the rack
(rack-mount library) must meet the following environmental
2
requirements:
humidity: 20% to 80%, non-condensing
temperature: 59 F to 90 F (15 C to 32 C)
altitude: sea level to 10,000 feet (3,033 meters)