To Configure The Trigger Out Smb Port - Agilent Technologies E5900B User Manual

Hide thumbs Also See for E5900B:
Table of Contents

Advertisement

To configure the Trigger Out SMB port

If you have an emulation probe, but you do not have an emulation
module, use the following table to configure the behavior of the Trigger
Out SMB connector on the front of the emulation probe.
If you have an emulation module, the trigger out behavior is always set
to monhigh for compatibility with intermodule triggering.
Trigger out configuration
Value
Emulation probe Trigger Out will be
monhigh
Logic high when the processor is running in
background (Default)
monlow
Logic low when the processor is running in
background
fixhigh
Fixed logic high
fixlow
Fixed logic low
Emulation for the Motorola M•CORE
Configuring the Emulation Probe
Built-in command
cf trigout=monhigh
cf trigout=monlow
cf trigout=fixhigh
cf trigout=fixlow
65

Advertisement

Table of Contents
loading