TX Power
CAUTION:
Connecting a signal of >200 mW to the ANT IN port can cause instrument damage
(although internal protection circuits can typically withstand a short-duration signal of
1 or 2 Watts). If the overpower circuit is triggered (signified by a warning message at
the top of the screen), remove the signal from the ANT IN port, and press the MEAS
RESET key or turn the Test Set off and on to reset it.
Transmitter Power measures RF power at the RF IN/OUT port.
Operating Considerations
Only the RF IN/OUT port can be used for measuring TX Power. When the
is set to
, four dashes (- - - -) appear in place of digits for this
Port
Ant
measurement.
Use the Spectrum Analyzer to measure low-level RF power (
ANT IN port.
See Also
Input Port field description, on page 277
TX Power field description, on page 437
TX Pwr Zero field description, on page 440
Screens Where Field is Present
ADJACENT CHANNEL POWER
ANALOG MEAS
DUPLEX TEST
AF ANALYZER
RF ANALYZER
RF GENERATOR
TX TEST
S:\hp8924c\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields That Begin with the Letter T
200 mW) at the
Input
437