HP 8924C Reference Manual page 266

Cdma mobile station test set
Hide thumbs Also See for 8924C:
Table of Contents

Advertisement

Chapter 4, Description of Fields
Fields That Begin with the Letter F
Frame Clock
Frames
266
This field is used to select the CDMA frame clock output frequency on the rear-
panel CDMA CLOCK MUX OUTPUT.
Operating Considerations
The CDMA frame clocks provide the CDMA timing references for generating and
demodulating CDMA signals.
The CELLSITE/TRIGGERS connector, a rear-panel miniature D-type 15-pin
connector provides all of the above frame clock outputs simultaneously. The
timing of these frame clocks may be offset slightly from the timing of the CDMA
CLOCK MUX OUTPUT's frame clocks due to propagation delays.
See Also
"CELL SITE/TRIGGERS" on page 69
"CDMA CLOCK MUX OUTPUT" on page 71
Screens Where Field is Present
CONFIGURE
This field indicates the number of frames counted during the reporting interval.
HP-IB Example
"DISP CMOB;CDMA:MOBile:FERasure:ERRors?"
queries the number of frames counted by the mobile station during an FER report
interval.
Operating Considerations
The reporting interval is specified in terms of error count or frame count.
See Also
by # errors field description, on page 185
by # frames field description, on page 186
MS FER Report Interval field description, on page 305
Screens Where Field is Present
CDMA MOBILE REPORTING
S:\hp8924c\REFGUIDE\MANUAL\fields.chp

Advertisement

Table of Contents
loading