Download Print this page
HP 8753ES Specifications

HP 8753ES Specifications

Network analyzers 30 khz to 3 or 6 ghz
Hide thumbs Also See for 8753ES:

Advertisement

Quick Links

8753ET/ES
HP 8753ET and 8753ES Network Analyzers
30 kHz to 3 or 6 GHz
This document describes the performance
and features of the following products:
HP 8753ES S-parameter vector network analyzer
HP 8753ES Option 011 vector network analyzer without test set
HP 8753ET Transmission/reflection vector network analyzer
For more information about these analyzers, please see the following documents:
HP 8753ET and 8753ES Network Analyzers Brochure
HP 8753ET and 8753ES Network Analyzers Configuration Guide
Network Analyzers
HP literature number
5968-5159E
5968-5158E

Advertisement

loading

Summary of Contents for HP 8753ES

  • Page 1 This document describes the performance and features of the following products: HP 8753ES S-parameter vector network analyzer HP 8753ES Option 011 vector network analyzer without test set HP 8753ET Transmission/reflection vector network analyzer For more information about these analyzers, please see the following documents:...
  • Page 2: Table Of Contents

    Table of contents Definitions and test conditions ......3 System performance summaries ......4 Specifications and characteristics .
  • Page 3: Definitions And Test Conditions

    The measurement uncertainty curves and measure- ment port characteristics given for HP 8753ES systems also apply to the HP 8753ES with Options 006 and 011 and the HP 85047A test set (50-ohm), or the HP 8753ES Option 011 with an HP 85046B test set (75-ohm).
  • Page 4: System Performance Summaries

    System performance summaries HP 8753ES (50-ohm systems) 7-mm test ports Configuration Network analyzer HP 8753ES Standard and Option 006 Calibration kit HP 85031B Test-port cables HP 11857D System dynamic range 30 kHz to 50 kHz 70 dB 50 kHz to 300 kHz...
  • Page 5 System performance summaries HP 8753ES (50-ohm systems) Type-N test ports Configuration Network analyzer HP 8753ES Standard and Option 006 Calibration kit HP 85032B Test-port cables HP 11857D System dynamic range 30 kHz to 50 kHz 70 dB 50 kHz to 300 kHz...
  • Page 6 System performance summaries HP 8753ES (50-ohm systems) 3.5-mm test ports Configuration Network analyzer HP 8753ES Standard and Option 006 Calibration kit HP 85033D Test-port cables HP 11857D System dynamic range 30 kHz to 50 kHz 70 dB 50 kHz to 300 kHz...
  • Page 7 System performance summaries HP 8753ES (75-ohm systems) Type-N test ports Configuration Network analyzer HP 8753ES Option 075 Calibration kit HP 85036B Test-port cables HP 11857B System dynamic range 30 kHz to 50 kHz 68 dB 50 kHz to 300 kHz...
  • Page 8 System performance summaries HP 8753ES (75-ohm systems) Type-F test ports Configuration Network analyzer HP 8753E Option 075 Calibration kit HP 85039B Test-port cables HP 11857B System dynamic range 30 kHz to 50 kHz 68 dB 50 kHz to 300 kHz...
  • Page 9 System performance summaries HP 8753ET (50-ohm systems) Type-N test ports Configuration Network analyzer HP 8753ET Standard, Option 006 or Option 004 Calibration kit HP 85032B Test port cable HP part number 8120-4781 System dynamic range 300 kHz to 16 MHz...
  • Page 10: Specifications And Characteristics

    5˚ C. 11. The HP 8753ES source characteristics and measurement accuracy in this mode are dependent on the stability of the external LO source. The RF source tracks the LO to maintain a stable IF signal at the R-channel receiver input. Degradation in accuracy is negligible when using an HP 8642A/B, 8656B, or E4432B RF signal generator as the LO source.
  • Page 11 300 kHz to 3 GHz < 0.006 dB rms 3 GHz to 6 GHz < 0.010 dB rms 1. See the HP 8753ES descriptions and options for a functional description. Measurement accuracy is dependent on the stability of the input signal. 2. Typical performance.
  • Page 12 3. 16 MHz to 3 GHz. 4. 16 MHz to 2 GHz. 5. For HP 8753ES Option 011 and Option 006, linearity is specified for the ranges of -5 to +13 dBm and +13 to +18 dBm. 6. Typical performance.
  • Page 13 2. Typical below 300 kHz. 3. The HP 8753ES source characteristics and measurement accuracy in this mode are dependent on the stability of the external LO source. The RF source tracks the LO to maintain a stable IF signal at the R-channel receiver input.
  • Page 14 Mixer related <-55 dBc at -10 dBm 1. Relative to -5 dBm output power for the HP 8753ET; -10 dBm output power for HP 8753ET with Option 004. 2. 16 MHz to 3 GHz. 3. 16 MHz to 2 GHz.
  • Page 15 < 0.006 dB rms 3 GHz to 6 GHz < 0.010 dB rms 1. See the HP 8753ET/ES descriptions and options for a functional description. Measurement accuracy is dependent on the stability of the input signal. 2. Typical performance. 3. Marker resolution for magnitude, phase and delay is dependent upon measured value. Resolution is limited to five digits.
  • Page 16 Measurement parameters HP 8753ET: Reflection, transmission, A, B, R, A/R, B/R, A/B. Conversion to impedance or admittance. HP 8753ES: S11, S21, S12, S22, A, B, R, A/R, B/R, A/B. Conversion to impedance or admittance. Formats log/linear magnitude, phase, group delay, Cartesian: SWR, real and imaginary.
  • Page 17 Reference plane extension Redefine the plane-of-measurement reference to other than port 1 or port 2 of the HP 8753ET and 8753ES. Select default calibration kit Select from a list of standard calibration kits or choose a user-defined kit.
  • Page 18 Centronics, RS-232C, and GP-IB interfaces. Data listings Printouts of instrument data are directly produced with a printer such as the HP DeskJet or LaserJet. Select black & white or color print. For a list of compatible printers, consult our printer-compatibility guide Web page at http://www.hp.com/go/pcg...
  • Page 19 Using a subset of HP Graphics Language (HP-GL), vector or text graphics may be written on the HP 8753ET/ES via GP-IB. Up to 5 kbytes of data can be stored at one time (4 bytes per vector, 2 bytes per character).
  • Page 20: General Characteristics

    This mini-DIN connector is used for adding an IBM PC-AT compatible keyboard. Test set interconnect This connector is used to connect an HP 8753ES Option 011 to the HP 85046A/B or 85047A test set. HP 8753ES analyzers without Option 011 can use sig- nal levels on this connector for sequencing or general purpose I/O applications.
  • Page 21: Measurement Throughput Summary

    2. Same as footnote 1, but for an S21 measurement with full two-port calibration. Includes RF switching time. 3. Option 010 only, gating off. 4. Measured with an HP Omnibook 7100 266 MHz Pentium 5. Does not include error from the HP 8753T/ES source and receiver harmonics. Measurement throughput summary The following table shows typical measurement times in milliseconds.
  • Page 22: Test Set Specifications For Option 011

    Option 011 and include a programmable step attenua- tor. The frequency range of the HP 85046A 50-ohm test set is 300 kHz to 3 GHz. The HP 85046A has preci- sion 7-mm connectors. The frequency range of the HP 85046B 75-ohm test set is 300 kHz to 2 GHz. The HP 85046B has 75-ohm type-N(f) connectors.
  • Page 23 This test set includes a frequency doubler that can be switched in by an HP 8753B/C Option 006 to measure 3 MHz to 6 GHz in a single sweep or switched out to measure 300 kHz to 3 GHz in a single sweep.
  • Page 24: Accessories

    DC to 6 GHz HP 85033D 3.5-mm calibration kit Contains a set of precision 3.5-mm standards to cali- brate the HP 8753ES and 50-ohm test sets for the measurement of devices with precision 3.5-mm and SMA connectors. Precision phase-matched 7-mm to 3.5-mm adapters are included for accurate measure-...
  • Page 25 3.5-mm female to 7-16 female adapter HP 85039B type-F calibration kit Contains a set of 75-ohm type-F standards to calibrate the HP 8753ES with a 75-ohm test set for the mea- surement of devices with type-F connectors. Includes F-male 75-ohm termination...
  • Page 26 > 30dB to 6 GHz HP 11857B 75-ohm type-N test port return cables A pair of 610-mm (24-in.) test port return cables for use with the HP 8753ES or HP 85046B 75-ohm S-para- meter test set. Return loss > 24 dB to 2 GHz Phase tracking ±2˚...
  • Page 27 The HP 11853A 50-ohm type-N and the HP 11854A 50-ohm BNC accessory kits provide the RF compo- nents generally required when using either the HP 85046A, 85047A or 11850C with the HP 8753ES Option 011 when measuring devices having 50-ohm type-N or BNC connectors. These kits are supplied with a storage case.
  • Page 28 HP 8347A RF amplifier The HP 8347A RF amplifier delivers increased power across a 300 kHz to 3 GHz frequency range. The HP 8347A provides leveled output power without using an external coupler and detector, since these parts are built-in. The external ALC can be directly connected to the external AM input on the HP 8753ET/ES.

This manual is also suitable for:

8753et