RANDSSD_3
RAND_U
RANDSSD_3 is the 8 least significant bits of the random number issued by the
base station in the SSD Update Order. RANDSSD_3 is entered as a 2-digit
hexadecimal value.
The :RAND:SSD3 command is used to control this field.
The query form (that is, :RAND:SSD3?) can be used to query the current field
value.
Syntax
:RAND:SSD3
:RAND:SSD3?
Example
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:SSD3 '4F'"
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:SSD3?"
ENTER 714;Rand_val$
Screens Where Field is Present
AUTHENTICATION
RAND_U is the 24-bit random number issued by the base station in the Unique
Challenge Order. RAND_U is entered as a 6-digit hexadecimal value. RAND__U
is user definable.
The :RAND:U command is used to control this field.
The query form (that is, :RAND:U?) can be used to query the current field value.
Syntax
:RAND:U <'><6 character hex value><'>
:RAND:U?
Example
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:U '4F5A55'"
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:U?"
ENTER 714;Rand_val$
Screens Where Field is Present
AUTHENTICATION