4. Determine the command code for
the transponder. It will be one of
13 letters, A through M.
5. Touch the Command setting.
The command code keypad opens
as shown in Figure 4-59.
6. Touch the required command
code.
The keypad closes and the code is
displayed as the Command setting.
7. Touch the Duration setting. A
duration of 8 is recommended.
The duration keypad opens as
shown in Figure 4-60.
8. Touch the required duration.
The keypad closes and the
duration is displayed as the
Duration setting.
WARNING Before proceeding with
the next step, verify that the
command code is correct.
9. Touch—and hold—Send.
Three short beeps followed by a long beep will be heard, and then the
Send button will become highlighted.
NOTE The command will be sent only after the Send button is released. To
abort the command, continue to maintain contact with the touch screen
display while sliding the finger completely off the Send button. The Send
button will become unhighlighted. If the command successfully aborts, a
pop-up will appear with the message "Transmission Aborted."
10. Release Send.
4
Operation using the Touch Screen Display
Figure 4-59 Command Code
Keypad

Figure 4-60 Duration Keypad

Sending Commands To Acoustic Releases