COMMAND NAME
Receive Pulse Duration
Receive Sensitivity
Date
Time
Transmit Frequency
Display Lockout
Power Output
Repeat Interval
Repeat Ping Status
Silent Ping
Ping Duration
Ping Lockout
Turnaround Compensation
Ping Command
Frequency Filter Status
Frequency Filter
Table 5-2 DS-7000 Write Commands
SYNTAX
RD #.## or RD=#.##
RS ### or RS=###
DA mm/dd/yy or DA=mm/dd/yy
TI hh:mm:ss or TI=hh:mm:ss
TX ##.## or TX=##.##
DL c or DL=c
PO # or PO=#
RI ##.# or RI=##.#
RP c or RP=c
SP c or SP=c
PD ##.# or PD=##.#
PL ### or PL=###
TC ##.# or TC=##.#
PI or PI <id> or PI=<id>
FS c or FS=c
FF ##.## ... ##.## or FF=##.##... ##.##
or
FF NONE or FF=NONE
RESPONSE
RD= #.## where x is 6.25 or 12.5 in milliseconds
RS=### where ### is 010 to 500
DA=mm/dd/yy
TI=hh:mm:ss
TX=##.## where ##.## is 07.00 to 15.00 in .25 incre-
ments
DL=c where c is E for enabled or D for disabled
PO=# where # is 0 through 8
RI=##.# where ##.# is 03.5 through 35.0
RP=c where c is E for enabled or D for disabled
SP=c where c is E for enabled or D for disabled
PD=##.# where ##.# is 10.0 to 25.0
PL=### where ### is 000 to 995 in steps of 5
TC=##.# where ##.# is 00.0 to 99.9 ms
PI=<id> tx.ff c mm/dd/yy hh:mm:ss where <id> is any
string, tx.ff is the transmit frequency, and c is S for
silent ping or N for normal ping. ## will be 00 if no
identifier was specified.
FS=c where c is E for enabled or D for disabled
FF=##.##... ##.## where ##.## is 07.00 to 15.00 in .25
increments.
or
FF=NONE