5.6
SMS/Call Settings
Essential fields in 'SMS' part is 'Login' and 'Password'. The login and password are used
with every SMS sent to FMB1YX. If login and password are not set, in every SMS sent to FMB1YX
device two spaces before command have to be used (<space><space><command>).
Command structure with set login and password:
<login><space><password><space><command>, example: "asd 123 getgps"
Phone numbers have to be written in international standard, with using "+" or without
using it (in both cases number will be recognized, but when number is without "+" symbol, it will
not generate IDD Prefix, which depends on location of phone). If no numbers are entered,
configuration and sending commands over SMS are allowed from all GSM numbers.
SMS data sending settings allows or does not allow sending AVL data using binary SMS. AVL
data will be send by SMS only when there are no GPRS connection. This setting does not affect
replies to SMS request messages – answers are always sent back to sender telephone number.
Incoming Call Settings
This parameter defines device action during incoming call:
Do Nothing
Hang up – automatically hang up incoming call
Report Position – Report position to calling number via SMS
Auto Answer (HF) – Auto answer incoming call if hands free device is connected. If
hands free device is not connected, then incoming call will be hanged up.
Hands free call functionality
When FMB1YX is connected to hands free headset it can call to user defined GSM
numbers.
Figure 14 SMS \ call Settings configuration