Teltonika FMB1YX User Manual page 195

Table of Contents

Advertisement

9.16.5 RS485
RS485 working mode (ID=160)
9.16.5.1
RS485 support several modes: 0 – log mode, 1 – NMEA, 2 – LLS, 7 – TCP ASCII, 8 – TCP
Binary.
Minimum
Maximum
value
value
0
4
RS485 Baudrate (ID=161)
9.16.5.2
Every RS232 mode support different Baudrate: 0 – default, 1 – 1200, 2 – 2400, 3 – 9600, 4 –
14400, 5 – 19200, 6 – 38400, 7 – 57600, 8 – 115200. Every mode default Baudrate are shown in
chapter RS232 Baudrate and parity, table 14.
Minimum
Maximum
value
value
0
8
9.16.6 RS485 LLS Sensors
LLS addresses may be configured for 5 LLS sensors.
LLS 1 Address (ID=162)
9.16.6.1
LLS fuel level sensor 1 address.
Minimum
Maximum
value
value
0
254
Default value
Goes with (depends on)
External UART working mode
RS485 Baudrate (ID=161)
3
Default value
Goes with (depends on)
External UART working mode
RS485 working mode (ID=160)
Depends on
selected mode
Default value
Goes with (depends on)
External UART working mode
RS485 working mode (ID=160)
RS485 Baudrate (ID=161)
0
parameters
(ID=150)
LLS 1 Address (ID=162)
LLS 2 Address (ID=163)
LLS 3 Address (ID=164)
LLS 4 Address (ID=165)
LLS 5 Address (ID=166)
parameters
(ID=150)
LLS 1 Address (ID=162)
LLS 2 Address (ID=163)
LLS 3 Address (ID=164)
LLS 4 Address (ID=165)
LLS 5 Address (ID=166)
parameters
(ID=150)
LLS 2 Address (ID=163)
LLS 3 Address (ID=164)
LLS 4 Address (ID=165)
LLS 5 Address (ID=166)
Value
type
Uint8
Value
type
Uint8
Value
type
Uint8
195