Teltonika FMB1YX User Manual page 103

Table of Contents

Advertisement

8.1.20 obdinfo
Response details
LIST of OBD info
Example:
"Prot:0,VIN:N/A,TM:10,CNT:0,ST:OFF,P1:0x0,P2:0x0,P3:0x0,P4:0x0,MIL:0,DTC:0,ID0,Hdr:0,Phy:0".
8.1.21 faultcodes
Response details
LIST
Example: "P0100,P0200,P0300,C0300,B0200,U0100".
8.1.22 setkey # #
"setkey <oldkeyword> <newkeyword>" - Set new or change the keyword. Configuration
should be not locked.
Example: New keyword (set):
<name>{space}<pass>{space}setkey{space}{space}<newkeyword>
Change keyword (change):
<name>{space}<pass>{space}setkey{space}<oldkeyword>{space}<newkeyword>
8.1.23 delkey # #
"delkey <keyword>" - Deletes current keyword. Configuration keyword should be
configured and not locked.
Example:
<name>{space}<pass>{space}delkey{space}<keyword>
8.1.24 bbread #
# describes start offset and is an optional field. # of value 20 means that blackbox data is
requested starting from 20
single SMS.
Example: X1:Y1,X2:Y2,...,Xn:Yn, where Xn – HEX value of event ID. Yn – HEX value of custom
data field (optional).
8.1.25 bbinfo #
# describes start offset and is an optional field. # of value 20 means that blackbox data is
requested starting from 20
single SMS.
Example: X1-Y1:Z1,X2-Y2:Z2,...,Xn-Yn:Zn, where Xn – timestamp in HEX. Yn – HEX value of
event ID. Zn – HEX value of custom data field (optional).
Description
Protocol, VIN, AdaptiveTiming value, requested PID counter, OBD
application state, available vehicle PIDs, mil status, number of
DTCs
Description
Returns list of fault codes; response when no faults: "No fault
codes detected."
th
latest event. When # is omitted the latest events are packet to
th
latest event. When # is omitted the latest events are packet to
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmb120Fmb122Fmb125

Table of Contents