Teltonika FMB1YX User Manual page 108

Table of Contents

Advertisement

9.1.13 Movement Stop Delay(s) (ID=19002)
What Accelerometer Ignition source delay will be after Ignition off.
Minimum
Maximum
value
value
5
60
9.1.14 Led indication (ID=108)
Sets led indication: 0 – disabled, 1 – enabled
Minimum
Maximum
value
value
0
1
9.1.15 Synchronization settings (ID=900)
Settings used for device internal time synchronization: 0 – GPS only, 1 – NITZ and NTP, 2 –
NTP, 3 – NITZ.
Minimum
Maximum
value
value
0
3
9.1.16 NTP Resync (ID=901)
Periodical time synchronization. If not zero FMB1YXx will resynchronize time once set
period expires.
Minimum
Maximum
value
value
0
24
9.1.17 NTP server 1 (ID=902)
Minimum
Maximum
value
value
55 char
0
string
Default value
Goes with (depends on)
Ignition settings (ID=101)
60
Movement Start Delay(s)
Default value
Goes with (depends on)
1
Default value
Goes with (depends on)
1
Default value
Goes with (depends on)
Synchronization settings
0
Default value
Goes with (depends on)
Synchronization settings
avl1.teltonika.lt
(ID=19002)
parameters
(ID=19001)
parameters
parameters
NTP Resync (ID=901)
NTP server 1 (ID=902)
NTP server 2 (ID=903)
parameters
(ID=900)
NTP server 1 (ID=902)
NTP server 2 (ID=903)
parameters
(ID=900)
NTP Resync (ID=901)
NTP server 2 (ID=903)
Value
type
Uint16
Value
type
Uint8
Value
type
Uint8
Value
type
Uint8
Value
type
S8[55]
108