7.3.10 Backup Server Protocol (ID=2009)

Parameter defines GPRS data transport protocol. Module can use TCP or UDP transport
protocol to send data to backup server. For TCP protocol value is 0, for UDP protocol value is 1.
Minimum
Maximum
value
value
0
1

7.3.11 Backup Server Mode (ID=2010)

Sets backup server mode: 0 – Disable (backup server not used), 1 – Backup (sent to backup
server if main server not available), 2 – Dublicate (send records to both servers).
Minimum
Maximum
value
value
0
2
7.4

SMS/Call settings

7.4.1

SMS data sending settings (ID=3000)

Parameter allows or does not allow sending AVL data using binary SMS. If SMS use is not
allowed value is 0 and 1 if SMS use is allowed.
Minimum
Maximum
value
value
0
1
7.4.2

Data send number (ID=3001)

In this field are written GSM numbers, to which will be sent Data SMS.
Minimum
Maximum
value
value
Empty
16 digits
7.4.3

Authorized phone numbers (ID=4000-4009)

If at least one number is entered then only those number can send messages to device.
Example: +37060012346
Minimum
Maximum
value
value
Empty
16 digits
Default value
Goes with (depends on)
GPRS content activation
0
Backup Server Mode (ID=2010)
Default value
Goes with (depends on)
GPRS content activation
0
Default value
Goes with (depends on)
0
Data send number (ID=3001)
Default value
Goes with (depends on)
SMS data sending settings
-
Default value
Goes with (depends on)
-
SMS Password (ID=3004)
parameters
(ID=2000)
parameters
(ID=2000)
parameters
parameters
(ID=3000)
parameters
SMS Login (ID=3003)
Digital Output control
Value
type
Uint8
Value
type
Uint8
Value
type
Uint8
Value
type
S8[16]
Value
type
S8[16]