Teltonika FMB1YX User Manual page 78

Table of Contents

Advertisement

Table 14. Default Baudrate and Parity by RS232/RS485 working Mode
Mode
RS232 default Baudrate
Log Mode
NMEA
LLS
LCD
RFID HID
RFID MF7
Garmin FMI
TCP ASCII
TCP Binary
RS232 TCP Binary mode settings
5.19.10.4
RS232 TCP Binary Mode has additional configurable parameters for advanced data filtering.
RS232 Garmin Mode settings
5.19.10.5
Garmin FMI mode has additional filtering capabilities. It is possible to filter Ping and
Unicode packets. If Ping filter will be enabled, then Ping packets will be blocked. If Unicode filter
will be enabled, then Unicode packets will not be sent to server. Both filters may be enabled for
simultaneous work.
RS485 working mode
5.19.10.6
RS485 support several modes:
 Log Mode – suitable for debugging/logging;
 NMEA – NMEA logs are sent via RS232 or RS485;
 LLS – LLS sensors support;
 TCP ASCII – for routing any input string from external device to server;
RS485 default Baudrate
115200
115200
19200
57600
57600
9600
9600
115200
115200
Figure 62 RS232 TCP Binary mode settings
Figure 63 RS232 Garmin Mode settings
Default Parity (RS232 only)
115200
115200
19200
-
-
-
-
57600
57600
None
None
None
None
None
None
None
None
None