9.1.5
Analog input value range (ID=111)
Sets AIN measurement range: 0 – 10 V, 0 – 30 V (for now 0 – 10 V range works same as 0 –
30 V range).
Minimum
Maximum
value
value
0
1
9.1.6
Static Navigation Settings (ID=112)
Sets static navigation exit (movement) detection sorces. 1 – Movement Source, 2 – Ignition
Source, 3 – both (Movement or ignition).
Minimum
Maximum
value
value
1
3
9.1.7
Saving/Sending without time synchronization (ID=107)
When this feature is enabled (value = 1), then records can be saved and sent to server
without time synchronization.
Minimum
Maximum
value
value
0
1
9.1.8
GNSS Source (ID=109)
This parameter sets Satellite System, available values:
0 – Undefined
2 – Glonass only
1– Beidou only
3 – Galileo+Beidou
Minimum
Maximum
value
value
0
15
9.1.9
Ignition settings (ID=101)
This parameter sets ignition source available values:
1 – Digital Input
Default value
0
Default value
1
Movement Source (ID=100)
Default value
1
4 – Galileo only
5 – Galileo+Beidou
6 – Galileo+Glonass
8 –
only
GPS
Default value
10
5 – Digital Input and
Power Voltage
Goes with (depends on)
parameters
Goes with (depends on)
parameters
Static Navigation (ID=106)
Ignition settings (ID=101)
Goes with (depends on)
parameters
9 –
+Beidou
GPS
10 –
+Glonass
GPS
12 –
+Galileo
GPS
13 –
+ Galileo + Beidou
GPS
Goes with (depends on)
parameters
9 – Digital Input and
Engine RPM
Value
type
Uint8
Value
type
Uint8
Value
type
Uint8
14–
+Galileo
GPS
+Glonass
15–
,Galileo,
GPS
Glonass and Beidou
and not allowed
Value
type
Uint8
13 – Digital Input,
Power Voltage and
Engine RPM
106