Operator search is performed every 15 minutes. Depending on current GSM operator,
Home, Roaming or Unknown mode can be changed faster than every 15 minutes. This process is
separate from operator search. Movement criteria are checked every second.
'Min Saved Records' defines minimum number of coordinates and I/O data that should be
transferred with one connection to server. If FMB1YX does not have enough coordinates to send
to server, it will check again after time interval defined in 'Sending Period'.
Send period – GPRS data sending to server period. Module makes attempts to send
collected data to server every defined period. If it does not have enough records (depends on
parameter Min. Saved Records described above), it tries again after defined time interval.
Note: Keep in mind that FMB1YX operates in GMT:0 time zone, without
daylight saving.
FMB1YX is able to collect records using four methods at the same time: time, distance,
angle and speed based data acquisition:
Time based data acquiring (Min. period) – records are being acquired every time when defined
interval of time passes. Entering zero disables data acquisition depending on time.
Figure 20 Data Acquisition Mode configuration