Teltonika FMB1YX User Manual page 114

Table of Contents

Advertisement

Minimum
Maximum
value
value
0
65535
9.2.22 FOTA WEB Period (min) (ID=13002)
Period defines how often device is going to connect to server.
Minimum
Maximum
value
value
30
65535
9.3
SMS/Call settings
9.3.1
SMS data sending settings (ID=3000)
Parameter allows or does not allow sending AVL data using binary SMS. If SMS use is not
allowed value is 0 and 1 if SMS use is allowed.
Minimum
Maximum
value
value
0
1
9.3.2
Data send number (ID=3001)
In this field are written GSM numbers, to which will be sent Data SMS.
Minimum
Maximum
value
value
Empty
16 digits
9.3.3
Authorized phone numbers (ID=4000-4199)
If at least one number is entered then only those number can send messages to device.
Example: +37060012346
Minimum
Maximum
value
value
Empty
16 digits
9.3.4
GSM Predefined Numbers (ID=6000-6009)
In this field GSM numbers are written, to which will be sent "Event SMS" text message.
Example: +37060012346
Goes with (depends on)
Default value
FOTA WEB status (ID=13003)
FOTA WEB Domain (ID=13000)
5000
FOTA WEB Period (min)
Goes with (depends on)
Default value
FOTA WEB status (ID=13003)
FOTA WEB Domain (ID=13000)
720
FOTA WEB port (ID=13001)
Default value
Goes with (depends on)
0
Data send number (ID=3001)
Default value
Goes with (depends on)
SMS data sending settings
-
Default value
Goes with (depends on)
SMS Password (ID=3004)
-
parameters
(ID=13002)
parameters
parameters
parameters
(ID=3000)
parameters
SMS Login (ID=3003)
Digital Output control
(ID=12000)
Value
type
Uint16
Value
type
Uint16
Value
type
Uint8
Value
type
S8[16]
Value
type
S8[16]