Obd Ii (Bluetooth) And Lvcan I/O Elements; Fmb125 Rs232\Rs485 Parameters Configuration; External Uart Working Mode - Teltonika FMB1YX User Manual

Table of Contents

Advertisement

configure 5 seconds averaging multiply 10 by 5 yielding 50. The same logic works even if
device is in deep sleep mode.
Averaging follows RC exponential curves, see image bellow:
For Boolean values 5τ, values is used, that means value change is taken when new values is
averaged to more then 99.3%.

5.19.9 OBD II (Bluetooth) and LVCAN I/O elements

In OBD II (Bluetooth) column are shown I/O elements which information can be obtained
from OBD II Bluetooth dongle connected to FMB1YX device and in LVCAN column are shown I/O
elements whitch information can be obtained from LV-CAN200 or ALL-CAN300 connected to
FMB1YX device. All I/O configuration is the same as described in 5.17 chapter (I/O settings),
except OBD II (Bluetooth) I/O element don't have averaging constant parameter.
Detailed description about LVAN I/O element configuration described in 8.5 chapter
(FMB1YX ALL-CAN300 and LV-CAN200 parameters configuration).

5.19.10 FMB125 RS232\RS485 parameters configuration

FMB125 device supports RS232 and RS485 serial communication transmission of data
standards and can be configured to work in different RS232/RS485 modes. More information
about eatch mode in 8 chapter (RS232 and RS485).

External UART working mode

5.19.10.1
FMB125 supports RS232 and RS485 modes. Only one mode may be selected for work at
one time:
 Disable - Disable RS232/RS485 functionality;
 RS232 - Select RS232 functionality;
 RS485 - Select RS485 functionality;
1
Only support FMB125 device
Figure 59 Averaging counting explanation
1
Figure 60 RS232 \ RS485 external UART working mode
76

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmb120Fmb122Fmb125