9.5.2.4
This parameter indicates speed difference in order to acquire new record. If speed
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. If value is 0 it means no records by min speed delta will be saved.
Minimum
Maximum
value
value
0
255
9.5.2.5
This parameter defines minimum number of records in one data packet that can be sent to
server. It has higher priority than Data Send Period (ID=10055).
Minimum
Maximum
value
value
1
255
9.5.2.6
This parameter indicates frequency (time interval in seconds) of sending data to server.
Minimum
Maximum
value
value
0
2592000
9.5.3
Roaming Network GSM operator code "Vehicle on STOP" parameters
9.5.3.1
This parameter indicates time interval in seconds in order to acquire new record. If value is
0 it means no records by min period will be saved.
Minimum
Maximum
value
value
0
2592000
Min Speed Delta (ID=10053)
Default value
Goes with (depends on)
Min Distance (ID=10051)
10
Min Saved Records (ID=10054)
Send Period (ID=10055)
Min Saved Records (ID=10054)
Default value
Goes with (depends on)
Min Distance (ID=10051)
1
Min Speed Delta (ID=10053)
Send Period (ID=10055)
Send Period (ID=10055)
Default value
120
Min Speed Delta (ID=10053)
Min Period (ID=10100)
Default value
3600
parameters
Min Period (ID=10050)
Min Angle (ID=10052)
parameters
Min Period (ID=10050)
Min Angle (ID=10052)
Goes with (depends on)
parameters
Min Period (ID=10050)
Min Distance (ID=10051)
Min Angle (ID=10052)
Min Saved Records
(ID=10054)
Goes with (depends on)
parameters
Min Saved Records
(ID=10104)
Value
type
Uint8
Value
type
Uint8
Value
type
Uint32
Value
type
Uint32