Teltonika FMB1YX User Manual page 42

Table of Contents

Advertisement

Figure 15 Hands Free Call Settings configuration for FMB120 and FMB122
Outgoing Call Trigger parameter determines which event will triggers call. FMB125
supports first for different call triggers and FMB120/FMB122 supports all eight call triggers:
 None selected – disables call trigger functionality.
 DIN1 – first digital input event triggers call to user selected GSM number.
 Crash Event – crash event triggers call to user selected GSM number.
 DIN1 and Crash Event – both events triggers call to user selected GSM number.
 DIN2 – seconf digital input event triggers call to user selected GSM number.
 DIN1 and DIN2 Event – both events triggers call to user selected GSM number.
 DIN2 and Crash Event – both events triggers call to user selected GSM number.
 DIN1, DIN2 and Crash Event – all events triggers call to user selected GSM
number.
SMS Event Time Zones
FMB1XX works with synchronized GPS time which is UTC+0, with this option customer can
configurate his time zone and get SMS with correct time.
Note: Please do not set Data Send Number to some cell phone number,
because it will not understand binary SMS. When sending a binary SMS to a
phone number, which is a server phone number, the server can interpret and
understand binary code, so the data can be read and you can view it on the
server.
SMS login and password and authorized number list are used to protect
FMB1YX module from unauthorized access. Module accepts messages only
from a list of authorized numbers and with proper module login and password.
Phone numbers have to be written in international standard, with using "+" or
without using it (in both cases number will be recognized). If no authorized
numbers are entered, module accepts messages from all numbers.