Teltonika FMB1YX User Manual page 121

Table of Contents

Advertisement

9.5.4.3
This parameter indicates angle in degrees in order to acquire new record. If angle
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. This parameter is operational, when speed is higher than 10km/h. If value
is 0 it means no records by min angle will be saved.
Minimum
Maximum
value
value
0
180
9.5.4.4
This parameter indicates speed difference in order to acquire new record. If speed
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. If value is 0 it means no records by min speed delta will be saved.
Minimum
Maximum
value
value
0
255
9.5.4.5
This parameter defines minimum number of records in one data packet that can be sent to
server. It has higher priority than Data Send Period (ID=10105).
Minimum
Maximum
value
value
1
255
9.5.4.6
This parameter indicates frequency (time interval in seconds) of sending data to server.
Minimum
Maximum
value
value
0
2592000
Min Angle (ID=10152)
Default value
Goes with (depends on)
Min Distance (ID=10151)
10
Min Speed Delta (ID=10153)
Min Saved Records (ID=10154)
Send Period (ID=10155)
Min Speed Delta (ID=10153)
Default value
Goes with (depends on)
Min Distance (ID=10151)
10
Min Saved Records (ID=10154)
Send Period (ID=10155)
Min Saved Records (ID=10154)
Default value
Goes with (depends on)
Min Distance (ID=10151)
1
Min Speed Delta (ID=10153)
Send Period (ID=10155)
Send Period (ID=10155)
Default value
120
parameters
Min Period (ID=10150)
parameters
Min Period (ID=10150)
Min Angle (ID=10152)
parameters
Min Period (ID=10150)
Min Angle (ID=10152)
Goes with (depends on)
parameters
Min Period (ID=10150)
Value
type
Uint8
Value
type
Uint8
Value
type
Uint8
Value
type
Uint32
121

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmb120Fmb122Fmb125

Table of Contents