GOX-2402MC-PGE | GOX-3201MC-PGE | GOX-5103MC-PGE | GOX-8901MC-PGE | GOX-12401MC-PGE
Internal Camera Blocks
To Use the Counter Function
Configure the settings as follows.
Four counters are available. Specify a counter (Counter0 to Counter3), and configure the settings.
Item
Counter 0 ~ 3
CounterEventSource
CounterEventActivation
Setting Value
Selectable Range
Counter 0 ~ 3
Counter0: Off, Frame Trigger
Counter1: Off, ExposureStart
Counter2: Off, SensorReadOut
Counter3: Off,
FrameTransferEnd
When the Counter function is
enabled:
Counter0, Counter1, Counter2 =
RisingEdge (Fixed)
Counter3 = FallingEdge (Fixed)
- 79 -
User Manual (Ver. 1.5) - Main Functions
Description
Select the counter.
Select the Counter Event signal for which to
read the count value.
When set to Off, the counter operation will
stop (but will not be reset).
Specify timing at which to count.