Changing The Frame Rate; Exposure Mode - JAI GOX-2402M-PGE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Hide thumbs Also See for GOX-2402M-PGE:
Table of Contents

Advertisement

GOX-2402MC-PGE | GOX-3201MC-PGE | GOX-5103MC-PGE | GOX-8901MC-PGE | GOX-12401MC-PGE

Changing the Frame Rate

When TriggerMode is disabled, you can change the frame rate in AcquisitionFrameRate.
Notes:
The shortest frame period varies depending on the ROI, pixel format, and binning mode
l
selected. The longest frame period is 0.125 Hz (8 sec.).
When TriggerMode[FrameStart] is enabled, the AcquisitionFrameRate setting is disabled.
l

Exposure Mode

Related Setting Items:
This camera has three Exposure modes (Off, Timed, TriggerWidth). Use the AcquisitionControl
settings to perform operations and settings for exposure.
ExposureMode = Off
Exposure control is not performed (free-running operation). The exposure time is the longest possible
time within the operating conditions such as the frame rate.
ExposureMode = Timed
Mode in which control is performed using ExposureTime. Acquire images using an exposure time
configured beforehand on an external trigger.
In this mode, the exposure time can be adjusted automatically by setting ExposureAuto. For details,
refer to
ALC (Automatic Level Control)
ExposureMode = TriggerWidth
Mode in which control of the exposure time is performed using the pulse width of the trigger input
signal. The exposure time will be the same as the pulse width of the trigger input signal.
Note: The settings for exposure control and triggers are related to each other. Be sure to
configure the settings described in
AcquisitionControl
Function.
Trigger
Control.
User Manual (Ver. 1.5) - Main Functions