2.12 H
ARDWARE
P
C
I
ORT
ARD
NSTALLATION
I
NSTALLATION
Adding or replacing Port Cards will require the system to be
taken out of service.
1) Wear a grounding strap or be sure to touch the metal case
frequently and avoid unnecessary movement while handling the
circuit boards.
2) Unplug the power supply to IVX.
3) Remove the case lid by removing the two
phillips screws.
The two Port Cards are located in the bottom
half of the cabinet– one behind the other. They
are ribbon cabled to the main board from a
connector in the upper left corner of the card.
The second Port Card (the uppermost card) will
need to be removed if access to the first card is
required.
4) Removal of Port Cards– Disconnect the
Amphenol connector from the card. Carefully
unplug the ribbon cable that runs to the main
board. Remove the 6 phillips screws and care-
fully remove the card from the cabinet.
5) Installation of Port Cards– observe the
locations and relative positions of the card over
the stand-offs. Install the 6 phillips screws,
connect the ribbon cable to the correct connec-
tor on the main board and connect the
Amphenol cable.
6) Power up IVX. The Power and Port Card
LEDs will blink three times when the power up
sequence is completed.