ESI ORIGINAL IVX Installation Manual page 93

Hide thumbs Also See for ORIGINAL IVX:
Table of Contents

Advertisement

IVX
T
S
ROUBLE
HOOTING
S
D
N
YSTEM
OES
OT
The following test procedures are designed to isolate a
failed component of the total installation. This might
include the System Cabinet, CO Line Ports, Station Ports,
wiring, Feature Phones, or system programming errors.
Note: Before performing any of the following checks, be
sure that the system is properly grounded and that a clean
power source is being used. Double check all wiring conti-
nuity before proceeding.
C
U
P
OME
P OR
OWER
Verify that intercom dial tone and the Idle LCD Display is
not available at all stations.
S
S
TATION
PECIFIC
If the above condition occurs at a single station, see
Station Inoperable.
S
-W
YSTEM
IDE
1. Check that the power transformer is solidly connected
at the 110v outlet and at the power jack of IVX.
2. Verify that the transformer is outputting 24v AC.
3. Remove the case lid and verify that all cables are thor-
oughly seated.
Note: When the system is powered-up, up to 45 seconds
may elapse before the software is fully loaded and the
Power LED lights.
T
ROUBLE
LED
L
DOES NOT
IGHT
S
5.1
HOOTING

Advertisement

Table of Contents
loading