Block Wiring Diagram - ESI ORIGINAL IVX Installation Manual

Hide thumbs Also See for ORIGINAL IVX:
Table of Contents

Advertisement

IVX
M
C
OUNTING THE
66 B
W
LOCK
IRING
ABINET
Use three #8 Hex Head screws. Note the position of the three
mounting holes in IVX. Also note that the top keyhole is slightly
off-center to the left.
1) Screw in the top screw to
the back board (at least 1/2
inch thick plywood) leaving
about 1/8th inch clearance
between the screw head and
the plywood.
2) Hang the unit using the
"keyhole" in the back of the
case.
3) Level the unit and install
the bottom two screws.
Attach the Power Transformer
to the wall allowing sufficient
length in both cords to reach the power connector on the upper
right side of the cabinet and to reach a standard 110v outlet.
Do not connect power until all hardware connections have
been made.
D
IAGRAM
Connect a standard male 50-pin Amphenol cable to each port
card female connector located on the bottom-right side of the
cabinet. The connector closest to the wall is the first card. Its 66
Block connects to the first 8 Stations, the 2 Analog Ports, the
Optional Serial Data Port, and the first 4 CO Lines. The second
Port Card connects to the second 8 Stations and the second 4
CO Lines. See Figure 1.
The Expansion Cabinet is required to add the third and fourth
Port Cards.