Safran CORTEX CRT Quantum User Manual page 79

Command ranging & telemetry unit
Table of Contents

Advertisement

Connector
Type
SMA Female
SMA Female
SMA Female
SMA Female
SMA Female
SMA Female
BNC Female
BNC Female
BNC Female
BNC Female
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Connector
Panel Label
TEST POINTS
Uplink video test signals
VIDEO OUT 1
(see section 2.3.4.1 for assignment to
Uplink video test signals
VIDEO OUT 2
(see section 2.3.4.1 for assignment to
significant from -20 dBm to –60 dBm,
AGC OUT 1
significant from 0 dBm to –100 dBm)
significant from -20 dBm to –60 dBm,
AGC OUT 2
significant from 0 dBm to –100 dBm)
significant from -20 dBm to –60 dBm,
AGC OUT 3
significant from 0 dBm to –100 dBm)
SMA-6
TIME & FREQUENCY
Reference time code input
IRIG IN
1-PPS IN
Reference 1-PPS clock input
5/10 MHz IN1
5/10 MHz IN2
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Signal
internal signals)
internal signals)
AGC voltage Output 1
Non coherent AGC :
Coherent IF level :
AGC voltage Output 2
Non coherent AGC :
Coherent IF level :
AGC voltage Output 3
Non coherent AGC :
Coherent IF level :
Reserved
(IRIG-B122)
Reference clock input # 1
Reference clock input # 2
Safran Data Systems
.
Ref.
Is.Rev.
Date:
30, 2021
Electrical characteristics
DC to 25 MHz (-3 dB attenuation)
2Vpp (adjustable, see note 1)
50 Ω
DC to 25 MHz (-3 dB attenuation)
2Vpp (adjustable, see note 1)
50 Ω
0 to 10 V, 10 dB/V
+ 2 V = -20 dBm,
+10 V = -100 dBm
Requires high impedance input
0 to 10 V, 10 dB/V
+ 2 V = -20 dBm,
+10 V = -100 dBm
Requires high impedance input
0 to 10 V, 10 dB/V
+ 2 V = -20 dBm,
+10 V = -100 dBm
Requires high impedance input
Reserved
0.1 to 6 Vpp
100 k Ω
LVTTL/TTL high imp
5, 10 or 100 MHz
0.2 to 5 Vpp
DC  4 V
50 Ω
5, 10 or 100 MHz
0.2 to 5 Vpp
DTU 100042