Safran CORTEX CRT Quantum User Manual page 75

Command ranging & telemetry unit
Table of Contents

Advertisement

C
C
ONNECTOR
ONNECTOR
T
P
YPE
ANEL
L
ABEL
BNC Female
SET #1
BNC Female
SET #2
BNC Female
SET #3
DA-15 Female
BNC Female
SET #4
DA-15 Female
BNC Female
VIDEO 1
BNC Female
VIDEO 2
BNC Female
AGC OUT 1
BNC Female
AGC OUT 2
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
C
MSP
ABLE
MODULE
S
LEEVE
CONNECTOR
L
ABEL
LABEL
TEST POINTS
Note 2
I/O NUM board
Note 2
I/O NUM board
Note 2
I/O NUM board
Note 2
I/O NUM board
VIDEO OUT 1
Note 3
VIDEO OUT 2
Note 3
Note 3
AGC OUT 1
AGC OUT 2
Note 3
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
SIGNAL
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
Uplink & downlink video test signals
(see section 2.3.4.1for assignment to internal
signals)
Uplink & downlink video test signals
(see section 2.3.4.1for assignment to internal
signals)
AGC voltage Output 1
Non coherent AGC :
significant from -20 dBm to –60 dBm,
Coherent IF level :
significant from 0 dBm to –100 dBm)
AGC voltage Output 1
Non coherent AGC :
significant from -20 dBm to –60 dBm,
Coherent IF level :
significant from 0 dBm to –100 dBm)
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
Date:
30, 2021
E
LECTRICAL CHARACTERISTICS
See section 2.3.4.2
See section 2.3.4.2
See section 2.3.4.2
See section 2.3.4.2
DC to 25 MHz (-3 dB attenuation)
2Vpp (adjustable, see note 4)
50 
DC to 25 MHz (-3 dB attenuation)
2Vpp (adjustable, see note 4)
50 
0 to 10 V, 10 dB/V
+
2 V = -20 dBm,
+10 V = -100 dBm
Requires
high impedance input
0 to 10 V, 10 dB/V
2 V = -20 dBm,
+
+10 V = -100 dBm
Requires
high impedance input
5.17
Dec. 03, 2021Sept.
Page 4

Advertisement

Table of Contents
loading

Table of Contents

Save PDF