Safran CORTEX CRT Quantum User Manual page 48

Command ranging & telemetry unit
Table of Contents

Advertisement

2Bn Carrier PLL BW (CRT XL Quantum)
2Bn Carrier PLL BW (CRT eXplorer)
Bit synchronizer PLL BW (2 Bn) Carrier loop bandwidth /10
BER degradation
Synchronization threshold
Eb/No measurement
1.6.1.4. Telemetry Processing
1.6.1.4.1. Low Bandwidth Telemetry
Input
Demodulation
Sub-Carrier Frequency
Bit Rate
Number of sub-carriers
Bandwidth
PSK demod./Bit sync. loop BW
Acquisition threshold (*)
Viterbi decoding
Viterbi depuncturing
PCM coding
BER degradation
Eb/No measurement
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
0.03, 0.1, 0.3, 1 and 3 % of symbol rate
0.01, 0.03, 0.1, 0.3, 1 and 3 % of symbol rate
User configurable (0.001% to 10%)
≤ 1 dB vs theory if BR < 10 Mbps, ≤ 2 dB if BR < 40 Mbps
In case of BP, DM: ≤ 1 dB if BR < 5 Mbps, ≤ 2 dB if BR < 10 Mbps
(always ensure the received spectrum fits to the 50-90 MHz IF Receiver
input bandwidth).
≤ 0 dB (Eb/No) for symbol rates ≥ 1 ksps (10 dB at 100 sps)
Yes (0.5 dB accuracy)
IF Receiver output
BPSK (direct bit synchronization available)
40 Hz to 128 kHz (512 kHz with LBW extension license)
Minimum: 10 bps or 7 bps with PACK-EXT license (NRZ code)
Maximum: 25 kbps or 64 kbps with LBW extension license
≤ 6
Automatically adjusted to the selected bit rate and sub-carrier frequency
10% / 10 % (Ultra Wide)
% of the Bit Rate 1% / 1% (Wide)
0.3% / 0.1% (Narrow)
Eb/No ≤ 0 dB (narrow BW), 2 dB (wide BW), 10 dB (Ultra Wide BW)
(*) at bit sync level
Rate 1/2 according to CCSDS 131.0-B-3 (§ 3.3)
Constraint length 7.
Rate 2/3, 3/4, 5/6, 7/8 CCSDS 131.0-B-3 (§ 3.4)
From 1/2 rate punctured code. Constraint length 7.
BP-L/M/S, NRZ-L/M/S
≤ 1 dB vs theory (typical)
Yes
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec. 03, 2021Sept.
30, 2021
Page 23