3.3.7.2. High Bandwidth TMU with Sub-carrier

a- Nominal case (TMU table/offset 26 = 0. GUI: Frame Sync. Input = Internal):
Aux. inputs
IF inputs
PM, FM
Aux. inputs
demodulator
b- External Input to Frame Synchronizer (TMU table/offset 26 = 1. GUI: Frame Sync. Input = Ext.
F/S):
Aux. inputs
IF inputs
PM, FM
Aux. inputs
demodulator
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
BPSK S/C,
Bi-phase, DM-M
PCM/PM, PCM/FM
demodulator
Bit synchronizer
Video
BPSK S/C,
PCM/PM, PCM/FM
Bi-phase, DM-M
demodulator
Bit synchronizer
Video
out
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Viterbi
decoder
decoder
(Option)
Viterbi
decoder
decoder
(Option)
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec.
03, 2021Sept. 30, 2021
Differential
Frame
decoder
Synchronizer
Differential
encoder
Invert/
swap
I out
(Option)
(Option)
I in
Differential
Frame
decoder
Synchronizer
Differential
encoder
Invert/
swap
I out
(Option)